7.8
CWE
125
Advisory Published
Updated

CVE-2013-2805

First published: Tue Mar 26 2019(Updated: )

Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it receives a datagram with an incorrect value in the “Record Data Size” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to an oversized value, an attacker could cause an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to this vulnerability can be found at the following Rockwell Automation Security Advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599

Credit: ics-cert@hq.dhs.gov

Affected SoftwareAffected VersionHow to fix
Rockwellautomation Rslinx Enterprise=5.10.00
Rockwellautomation Rslinx Enterprise=5.10.01
Rockwellautomation Rslinx Enterprise=5.20.00
Rockwellautomation Rslinx Enterprise=5.21.00
Rockwellautomation Rslinx Enterprise=5.30.00
Rockwellautomation Rslinx Enterprise=5.40.00
Rockwellautomation Rslinx Enterprise=5.50.00
Rockwellautomation Rslinx Enterprise=5.51.00
Rockwellautomation Rslinx Enterprise=5.60.00

Never miss a vulnerability like this again

Sign up to SecAlerts for real-time vulnerability data matched to your software, aggregated from hundreds of sources.

Frequently Asked Questions

  • What is the severity of CVE-2013-2805?

    The severity of CVE-2013-2805 is high with a severity value of 7.5.

  • Which software versions of Rockwell Automation RSLinx Enterprise are affected by CVE-2013-2805?

    The software versions affected by CVE-2013-2805 are 5.10.00, 5.10.01, 5.20.00, 5.21.00, 5.30.00, 5.40.00, 5.50.00, 5.51.00, and 5.60.00.

  • What is the logic error caused by CVE-2013-2805?

    CVE-2013-2805 causes a logic error if it receives a datagram with an incorrect value in the 'Record Data Size' field.

  • What is the Common Weakness Enumeration (CWE) ID for CVE-2013-2805?

    The Common Weakness Enumeration (CWE) ID for CVE-2013-2805 is 125.

  • Where can I find more information about CVE-2013-2805?

    You can find more information about CVE-2013-2805 at https://ics-cert.us-cert.gov/advisories/ICSA-13-095-02.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.