First published: Tue Mar 26 2019(Updated: )
Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “Total Record Size” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to a specifically oversized value, the service will calculate an undersized value for the “Total Record Size” that will cause an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation Security Advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599
Credit: ics-cert@hq.dhs.gov
Affected Software | Affected Version | How to fix |
---|---|---|
Rockwellautomation Rslinx Enterprise | =5.10.00 | |
Rockwellautomation Rslinx Enterprise | =5.10.01 | |
Rockwellautomation Rslinx Enterprise | =5.20.00 | |
Rockwellautomation Rslinx Enterprise | =5.21.00 | |
Rockwellautomation Rslinx Enterprise | =5.30.00 | |
Rockwellautomation Rslinx Enterprise | =5.40.00 | |
Rockwellautomation Rslinx Enterprise | =5.50.00 | |
Rockwellautomation Rslinx Enterprise | =5.51.00 | |
Rockwellautomation Rslinx Enterprise | =5.60.00 |
Sign up to SecAlerts for real-time vulnerability data matched to your software, aggregated from hundreds of sources.
The severity of CVE-2013-2807 is high with a severity value of 7.5.
Rockwell Automation RSLinx Enterprise Software is a software used for communication between industrial control system devices.
The following versions of Rockwell Automation RSLinx Enterprise Software are affected: 5.10.00, 5.10.01, 5.20.00, 5.21.00, 5.30.00, 5.40.00, 5.50.00, 5.51.00, 5.60.00.
The vulnerability in the LogReceiver.exe component of Rockwell Automation RSLinx Enterprise Software can result in a logic error if it calculates an incorrect value for the 'Total Record Size' field.
A fix or patch may be available from Rockwell Automation to address the vulnerability. It is recommended to refer to the official advisory for mitigation steps.