CVE-2017-7901: Critical severity rockwell automation 1763-l16awa series a vulnerability

Published Jun 30, 2017
·
Updated

A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. Insufficiently random TCP initial sequence numbers are generated, which may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections, resulting in a denial of service for the target device.

Affected Software

22 affected components
rockwellautomation 1763-l16awa Series A<=16.000
rockwellautomation 1763-l16awa Series B<=16.000
rockwellautomation 1763-l16bbb Series A<=16.000
rockwellautomation 1763-l16bbb Series B<=16.000
rockwellautomation 1763-l16bwa Series A<=16.000
rockwellautomation 1763-l16bwa Series B<=16.000
rockwellautomation 1763-l16dwd Series A<=16.000
rockwellautomation 1763-l16dwd Series B<=16.000
rockwellautomation Ab Micrologix Controller=1100
rockwellautomation 1766-l32awa Series A<=16.000
rockwellautomation 1766-l32awa Series B<=16.000
rockwellautomation 1766-l32awaa Series A<=16.000
rockwellautomation 1766-l32awaa Series B<=16.000
rockwellautomation 1766-l32bwa Series A<=16.000
rockwellautomation 1766-l32bwa Series B<=16.000
rockwellautomation 1766-l32bwaa Series A<=16.000
rockwellautomation 1766-l32bwaa Series B<=16.000
rockwellautomation 1766-l32bxb Series A<=16.000
rockwellautomation 1766-l32bxb Series B<=16.000
rockwellautomation 1766-l32bxba Series A<=16.000
rockwellautomation 1766-l32bxba Series B<=16.000
rockwellautomation Ab Micrologix Controller=1400

Event History

Jun 30, 2017
CVE Published
via MITRE·02:35 AM
Data Sourced
via MITRE·02:35 AM
DescriptionWeakness

Frequently Asked Questions

1

What is the severity of CVE-2017-7901?

CVE-2017-7901 is classified as a medium severity vulnerability.

2

How do I fix CVE-2017-7901?

To fix CVE-2017-7901, update the affected Rockwell Automation MicroLogix 1100 programmable-logic controllers to the latest firmware version beyond 16.00.

3

What systems are affected by CVE-2017-7901?

CVE-2017-7901 affects Rockwell Automation Allen-Bradley MicroLogix 1100 controllers, specifically the Series A and B versions with firmware version 16.00 and prior.

4

What is the nature of the vulnerability CVE-2017-7901?

CVE-2017-7901 involves a predictable value range derived from previous values, which could lead to unauthorized access or manipulation.

5

Is CVE-2017-7901 publicly known?

Yes, CVE-2017-7901 is publicly disclosed and documented in security vulnerability databases.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.