CVE-2017-8411: Command Injection

Published Jul 2, 2019
·
Updated

An issue was discovered on D-Link DCS-1130 devices. The device provides a user with the capability of setting a SMB folder for the video clippings recorded by the device. It seems that the POST parameters passed in this request (to test if email credentials and hostname sent to the device work properly) result in being passed as commands to a "system" API in the function and thus result in command injection on the device. If the firmware version is dissected using binwalk tool, we obtain a cramfs-root archive which contains the filesystem set up on the device that contains all the binaries. The library "libmailutils.so" is the one that has the vulnerable function "sub1FC4" that receives the values sent by the POST request. If we open this binary in IDA-pro we will notice that this follows an ARM little endian format. The function sub1FC4 in IDA pro is identified to be receiving the values sent in the POST request and the value set in POST parameter "receiver1" is extracted in function "sub15AC" which is then passed to the vulnerable system API call. The vulnerable library function is accessed in "cgibox" binary at address 0x00023BCC which calls the "Sendmail" function in "libmailutils.so" binary as shown below which results in the vulnerable POST parameter being passed to the library which results in the command injection issue.

Affected Software

2 affected components
Dlink Dcs-1130 Firmware
Dlink DCS-1130

Event History

Jul 2, 2019
CVE Published
via MITRE·06:44 PM
Data Sourced
via MITRE·06:44 PM
Description
Free Weekly Intel

Don't miss critical vulnerabilities

Join thousands of security professionals who receive our weekly digest of trending CVEs, zero-days, and exploited vulnerabilities.

No spam. Unsubscribe anytime.

Frequently Asked Questions

1

What is CVE-2017-8411?

CVE-2017-8411 is a vulnerability found on D-Link DCS-1130 devices that allows an attacker to execute arbitrary code via a crafted email credential and hostname.

2

How severe is CVE-2017-8411?

CVE-2017-8411 has a severity score of 8.8 (Critical) out of 10.

3

How does CVE-2017-8411 affect D-Link DCS-1130 devices?

CVE-2017-8411 affects D-Link DCS-1130 devices by allowing an attacker to execute arbitrary code via a crafted email credential and hostname.

4

What is the Common Weakness Enumeration (CWE) ID for CVE-2017-8411?

The Common Weakness Enumeration (CWE) ID for CVE-2017-8411 is 77.

5

Are there any references available for CVE-2017-8411?

Yes, there are references available for CVE-2017-8411. You can find them at the following links: [link1], [link2], [link3].

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.