CVE-2018-7234: High severity Schneider-electric Mps110-1 Firmware vulnerability

Published Mar 9, 2018
·
Updated

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of SSL certificate.

Affected Software

80 affected components
Schneider-electric Mps110-1 Firmware<3.29.67
Schneider-electric Mps110-1
Schneider-electric Imps110-1er Firmware<3.29.67
Schneider-electric Imps110-1er
Schneider-electric Ibps110-1er Firmware<3.29.67
Schneider-electric Ibps110-1er
Schneider-electric Imp1110-1 Firmware<3.29.67
Schneider-electric Imp1110-1
Schneider-electric Imp1110-1e Firmware<3.29.67
Schneider-electric Imp1110-1e
Schneider-electric Imp1110-1er Firmware<3.29.67
Schneider-electric Imp1110-1er
Schneider-electric Ibp1110-1er Firmware<3.29.67
Schneider-electric Ibp1110-1er
Schneider-electric Imp219-1 Firmware<3.29.67
Schneider-electric Imp219-1
Schneider-electric Imp219-1e Firmware<3.29.67
Schneider-electric Imp219-1e
Schneider-electric Imp219-1er Firmware<3.29.67
Schneider-electric Imp219-1er
Schneider-electric Ibp219-1er Firmware<3.29.67
Schneider-electric Ibp219-1er
Schneider-electric Imp319-1 Firmware<3.29.67
Schneider-electric Imp319-1
Schneider-electric Imp319-1e Firmware<3.29.67
Schneider-electric Imp319-1e
Schneider-electric Ibp319-1er Firmware<3.29.67
Schneider-electric Ibp319-1er
Schneider-electric Imp519-1 Firmware<3.29.67
Schneider-electric Imp519-1
Schneider-electric Imp319-1er Firmware<3.29.67
Schneider-electric Imp319-1er
Schneider-electric Imp519-1e Firmware<3.29.67
Schneider-electric Imp519-1e
Schneider-electric Imp519-1er Firmware<3.29.67
Schneider-electric Imp519-1er
Schneider-electric Ibp519-1er Firmware<3.29.67
Schneider-electric Ibp519-1er
Schneider-electric Imps110-1e Firmware<3.29.67
Schneider-electric Imps110-1e
All of the following
Schneider-electric Mps110-1 Firmware<3.29.67
Schneider-electric Mps110-1
All of the following
Schneider-electric Imps110-1er Firmware<3.29.67
Schneider-electric Imps110-1er
All of the following
Schneider-electric Ibps110-1er Firmware<3.29.67
Schneider-electric Ibps110-1er
All of the following
Schneider-electric Imp1110-1 Firmware<3.29.67
Schneider-electric Imp1110-1
All of the following
Schneider-electric Imp1110-1e Firmware<3.29.67
Schneider-electric Imp1110-1e
All of the following
Schneider-electric Imp1110-1er Firmware<3.29.67
Schneider-electric Imp1110-1er
All of the following
Schneider-electric Ibp1110-1er Firmware<3.29.67
Schneider-electric Ibp1110-1er
All of the following
Schneider-electric Imp219-1 Firmware<3.29.67
Schneider-electric Imp219-1
All of the following
Schneider-electric Imp219-1e Firmware<3.29.67
Schneider-electric Imp219-1e
All of the following
Schneider-electric Imp219-1er Firmware<3.29.67
Schneider-electric Imp219-1er
All of the following
Schneider-electric Ibp219-1er Firmware<3.29.67
Schneider-electric Ibp219-1er
All of the following
Schneider-electric Imp319-1 Firmware<3.29.67
Schneider-electric Imp319-1
All of the following
Schneider-electric Imp319-1e Firmware<3.29.67
Schneider-electric Imp319-1e
All of the following
Schneider-electric Ibp319-1er Firmware<3.29.67
Schneider-electric Ibp319-1er
All of the following
Schneider-electric Imp519-1 Firmware<3.29.67
Schneider-electric Imp519-1
All of the following
Schneider-electric Imp319-1er Firmware<3.29.67
Schneider-electric Imp319-1er
All of the following
Schneider-electric Imp519-1e Firmware<3.29.67
Schneider-electric Imp519-1e
All of the following
Schneider-electric Imp519-1er Firmware<3.29.67
Schneider-electric Imp519-1er
All of the following
Schneider-electric Ibp519-1er Firmware<3.29.67
Schneider-electric Ibp519-1er
All of the following
Schneider-electric Imps110-1e Firmware<3.29.67
Schneider-electric Imps110-1e

Remediation

Recommended actions to resolve this vulnerability, in priority order.

  1. Upgrade

    Upgrade Schneider Electric Pelco Sarix Professional to a version that resolves this vulnerability.

    Fixed in 3.29.67

Event History

Mar 9, 2018
CVE Published
via MITRE·11:00 PM
Data Sourced
via MITRE·11:00 PM
DescriptionWeakness
Data Sourced
via NVD·11:29 PM
RemedyDescriptionSeverityWeaknessAffected Software
Free Weekly Intel

Don't miss critical vulnerabilities

Join thousands of security professionals who receive our weekly digest of trending CVEs, zero-days, and exploited vulnerabilities.

No spam. Unsubscribe anytime.

Frequently Asked Questions

1

What is the severity of CVE-2018-7234?

CVE-2018-7234 has a severity rating that indicates it could lead to unauthorized access due to arbitrary file downloads.

2

How do I fix CVE-2018-7234?

To fix CVE-2018-7234, update your firmware to version 3.29.67 or later for affected Schneider Electric devices.

3

What systems are affected by CVE-2018-7234?

CVE-2018-7234 affects all versions of Schneider Electric's Pelco Sarix Professional firmware prior to 3.29.67.

4

What type of vulnerability is CVE-2018-7234?

CVE-2018-7234 is an SSL certificate validation vulnerability that allows for arbitrary file downloads.

5

Can CVE-2018-7234 be exploited remotely?

Yes, CVE-2018-7234 can be exploited remotely due to the lack of SSL certificate validation.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203