First published: Mon Oct 28 2019(Updated: )
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world-readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an attacker to read sensitive configuration settings such as usernames, passwords, and other sensitive RTU data due to insecure permission assignment.
Credit: cve@mitre.org cve@mitre.org
Affected Software | Affected Version | How to fix |
---|---|---|
Mitsubishielectric Smartrtu Firmware | <=2.02 | |
Mitsubishielectric Smartrtu | ||
Inea Me-rtu Firmware | <=3.0 | |
INEA ME-RTU | ||
All of | ||
Mitsubishielectric Smartrtu | ||
Mitsubishielectric Smartrtu Firmware | <=2.02 | |
All of | ||
INEA ME-RTU | ||
Inea Me-rtu Firmware | <=3.0 |
Sign up to SecAlerts for real-time vulnerability data matched to your software, aggregated from hundreds of sources.
CVE-2019-14925 is a vulnerability found in Mitsubishi Electric ME-RTU devices and INEA ME-RTU devices that allows an attacker to read sensitive configuration settings.
An attacker can exploit CVE-2019-14925 by accessing the world-readable /usr/smartrtu/init/settings.xml configuration file on the file system.
An attacker can obtain sensitive configuration settings such as usernames, passwords, and other data.
Mitsubishi Electric ME-RTU devices through version 2.02 and INEA ME-RTU devices through version 3.0 are affected by CVE-2019-14925.
CVE-2019-14925 has a severity rating of 6.5, which is considered medium.
To mitigate CVE-2019-14925, it is recommended to apply the necessary security updates or patches provided by Mitsubishi Electric or INEA.