CVE-2020-16225: Delta Industrial Automation TPEditor TPE File Parsing Write-what-where Condition Remote Code Execution Vulnerability

Published Aug 6, 2020
·
Updated

Delta Electronics TPEditor Versions 1.97 and prior. A write-what-where condition may be exploited by processing a specially crafted project file. Successful exploitation of this vulnerability may allow an attacker to read/modify information, execute arbitrary code, and/or crash the application.

Other sources

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Industrial Automation TPEditor. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of TPE files. The issue results from the lack of proper validation of user-supplied data, which can result in a write-what-where condition. An attacker can leverage this vulnerability to execute code in the context of the current process.

ZDI

Affected Software

3 affected components
Delta Electronics TPEditor Versions 1.97 and prior
Deltaww Tpeditor<=1.97
Delta Industrial Automation TPEditor

Event History

Aug 6, 2020
CVE Published
via MITRE·11:14 PM
Data Sourced
via MITRE·11:14 PM
DescriptionWeakness
Feb 27, 2025
Advisory Published
via ZDI·06:44 PM

Parent advisories

This vulnerability appears in the following advisories.

Free Weekly Intel

Don't miss critical vulnerabilities

Join thousands of security professionals who receive our weekly digest of trending CVEs, zero-days, and exploited vulnerabilities.

No spam. Unsubscribe anytime.

Frequently Asked Questions

1

What is the severity of CVE-2020-16225?

The severity of CVE-2020-16225 is high, with a CVSS score of 7.8.

2

How does CVE-2020-16225 impact Delta Industrial Automation TPEditor?

CVE-2020-16225 allows remote attackers to execute arbitrary code on affected installations of Delta Industrial Automation TPEditor.

3

Is user interaction required to exploit CVE-2020-16225?

Yes, user interaction is required to exploit CVE-2020-16225. The target must visit a malicious page or open a malicious file.

4

Which version of Delta Industrial Automation TPEditor is affected by CVE-2020-16225?

Delta Industrial Automation TPEditor version 1.97 and below are affected by CVE-2020-16225.

5

Where can I find more information about CVE-2020-16225?

You can find more information about CVE-2020-16225 on the following websites: 1. [US-CERT Advisory](https://us-cert.cisa.gov/ics/advisories/icsa-20-219-04) 2. [Zero Day Initiative Advisory](https://www.zerodayinitiative.com/advisories/ZDI-20-964/)

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.