First published: Tue Apr 13 2021(Updated: )
An exploitable SQL injection vulnerability exists in ‘getAssets.jsp’ page of OpenClinic GA 5.173.3 in the serviceUID parameter. An attacker can make an authenticated HTTP request to trigger this vulnerability.
Credit: talos-cna@cisco.com
Affected Software | Affected Version | How to fix |
---|---|---|
OpenClinic GA | =5.173.3 |
Sign up to SecAlerts for real-time vulnerability data matched to your software, aggregated from hundreds of sources.
CVE-2020-27234 is an SQL injection vulnerability in the 'getAssets.jsp' page of OpenClinic GA 5.173.3.
CVE-2020-27234 has a severity rating of 9.8 (Critical).
CVE-2020-27234 allows an attacker to exploit a SQL injection vulnerability in the 'getAssets.jsp' page of OpenClinic GA 5.173.3 by making an authenticated HTTP request with a malicious serviceUID parameter.
OpenClinic GA 5.173.3 is affected by CVE-2020-27234.
At the time of this writing, there is no known fix or patch for CVE-2020-27234. It is recommended to update to a newer version of OpenClinic GA when a fix becomes available.