First published: Mon Nov 16 2020(Updated: )
Garmin Forerunner 235 before 8.20 is affected by: Integer Overflow. The component is: ConnectIQ TVM. The attack vector is: To exploit the vulnerability, the attacker must upload a malicious ConnectIQ application to the ConnectIQ store. The ConnectIQ program interpreter fails to check for overflow when allocating the array for the NEWA instruction. This a constrained read/write primitive across the entire MAX32630 address space. A successful exploit would allow a ConnectIQ app store application to escape and perform activities outside the restricted application execution environment.
Credit: cve@mitre.org
Affected Software | Affected Version | How to fix |
---|---|---|
Garmin Forerunner 235 Firmware | >=7.90<8.20 | |
Garmin Forerunner 235 Firmware |
Sign up to SecAlerts for real-time vulnerability data matched to your software, aggregated from hundreds of sources.
CVE-2020-27484 is classified as a moderate severity vulnerability due to its potential impact through integer overflow.
To fix CVE-2020-27484, update the Garmin Forerunner 235 firmware to version 8.20 or later.
CVE-2020-27484 affects the ConnectIQ TVM component in Garmin Forerunner 235 firmware versions prior to 8.20.
The attack vector for CVE-2020-27484 involves uploading a malicious ConnectIQ application to the ConnectIQ store.
CVE-2020-27484 is an integer overflow vulnerability that allows an attacker to exploit the ConnectIQ program interpreter.