First published: Fri Jul 24 2020(Updated: )
IBM Intelligent Operations Center for Emergency Management, Intelligent Operations Center (IOC) is vulnerable to cross-site scripting. This vulnerability allows users to embed arbitrary JavaScript code in the Web UI thus altering the intended functionality potentially leading to credentials disclosure within a trusted session.
Credit: psirt@us.ibm.com
Affected Software | Affected Version | How to fix |
---|---|---|
IBM Intelligent Operations Center | =5.1.0 | |
IBM Intelligent Operations Center | =5.1.0.2 | |
IBM Intelligent Operations Center | =5.1.0.3 | |
IBM Intelligent Operations Center | =5.1.0.4 | |
IBM Intelligent Operations Center | =5.1.0.6 | |
IBM Intelligent Operations Center | =5.2 | |
IBM Intelligent Operations Center | =5.2.1 | |
IBM Intelligent Operations Center for Emergency Management | =5.1.0 | |
IBM Intelligent Operations Center for Emergency Management | =5.1.0.2 | |
IBM Intelligent Operations Center for Emergency Management | =5.1.0.3 | |
IBM Intelligent Operations Center for Emergency Management | =5.1.0.4 | |
IBM Intelligent Operations Center for Emergency Management | =5.1.0.6 | |
IBM Water Operations for Waternamics | =5.1.0 | |
IBM Water Operations for Waternamics | =5.1.0.3 | |
IBM Water Operations for Waternamics | =5.1.0.4 | |
IBM Water Operations for Waternamics | =5.1.0.6 | |
IBM Water Operations for Waternamics | =5.2 | |
IBM Water Operations for Waternamics | =5.2.1 | |
<=5.1.0, 5.1.0.2, 5.1.0.3, 5.1.0.4, 5.1.0.6, 5.2, 5.2.1 | ||
<=5.1.0, 5.1.0.2, 5.1.0.3, 5.1.0.4, 5.1.0.6, 5.2, 5.2.1 | ||
<=5.1.0, 5.1.0.2, 5.1.0.3, 5.1.0.4, 5.1.0.6 |
Sign up to SecAlerts for real-time vulnerability data matched to your software, aggregated from hundreds of sources.
CVE-2020-4318 is a vulnerability that allows users to embed arbitrary JavaScript code in the web user interface of IBM Intelligent Operations Center for Emergency Management, Intelligent Operations Center (IOC), and IBM Water Operations for Waternamics, leading to cross-site scripting.
IBM Intelligent Operations Center (IOC), IBM Water Operations for Waternamics, and IBM Intelligent Operations Center for Emergency Management (Linux) versions 5.1.0, 5.1.0.2, 5.1.0.3, 5.1.0.4, 5.1.0.6, 5.2, and 5.2.1 are affected.
CVE-2020-4318 has a severity value of 5.4, which is considered medium.
CVE-2020-4318 allows attackers to inject malicious JavaScript code into the web UI of the affected software, potentially compromising the integrity and security of the system.
Yes, IBM has released patches to address the vulnerability. It is recommended to update to the latest version of the affected software to mitigate the risk.