First published: Wed Nov 18 2020(Updated: )
A CWE-787: Out-of-bounds Write vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause corruption of data, a crash, or code execution when uploading a specially crafted file on the controller over FTP.
Credit: cybersecurity@se.com
Affected Software | Affected Version | How to fix |
---|---|---|
schneider-electric Modicon tsxety4103 | ||
schneider-electric Modicon TSXETY4103 Firmware | ||
Schneider Electric Modicon TSXETY5103 Firmware | ||
Schneider Electric Modicon TSXETY5103 Firmware | ||
Schneider Electric Modicon TSXP574634 Firmware | ||
Schneider Electric Modicon TSXP574634 Firmware | ||
Modicon TSXP575634 | ||
Modicon TSXP575634 | ||
Schneider Electric Modicon TSXP576634 | ||
schneider-electric Modicon tsxp576634 firmware | ||
Schneider Electric Modicon Quantum Firmware | ||
Schneider-electric Quantum Ethernet Module 140noe77101 | ||
schneider-electric Modicon Quantum 140noe77111 firmware | ||
Modicon Quantum 140NOE77111 | ||
Modicon Quantum 140noc78100 | ||
Modicon Quantum 140noc78100 | ||
Schneider Electric Modicon Quantum Firmware | ||
schneider-electric Modicon Quantum 140cpu65150 firmware | ||
Schneider Electric Modicon Quantum 140CPU65160C Firmware | ||
schneider-electric Modicon Quantum 140cpu65150c firmware | ||
schneider-electric Modicon Quantum 140cpu65160c | ||
Schneider Electric Modicon Quantum 140CPU65160C Firmware | ||
schneider-electric Modicon Quantum 140cpu65160 firmware | ||
schneider-electric Modicon Quantum 140cpu65160c | ||
Schneider Electric Modicon M340 Firmware | ||
Modicon M340 | ||
Schneider Electric Modicon M340 BMX P34-2030 Firmware | ||
Schneider Electric Modicon M340 | ||
schneider-electric Modicon M340 | ||
Schneider Electric Modicon M340 BMXNOC0401 | ||
Schneider Electric Modicon M340 BMX NOE 0100 Firmware | ||
Schneider Electric Modicon M340 BMX NOE 0100 Firmware | ||
Schneider Electric Modicon M340 BMX NOE 0100H Firmware | ||
Schneider Electric Modicon M340 BMX NOE 0100H Firmware | ||
schneider-electric Modicon M340 | ||
Schneider Electric Modicon M340 BMX NOE 0110H | ||
Schneider Electric Modicon M340 BMX NOE 0110H Firmware | ||
Schneider Electric Modicon M340 BMX NOE 0110H | ||
Schneider Electric Modicon M340 BMX NOR 0200H Firmware | ||
Schneider Electric Modicon M340 |
Sign up to SecAlerts for real-time vulnerability data matched to your software, aggregated from hundreds of sources.
CVE-2020-7563 is classified as a critical severity vulnerability due to its potential for data corruption, crashes, and code execution.
To fix CVE-2020-7563, users should update their affected Schneider Electric Modicon devices with the latest firmware versions.
CVE-2020-7563 affects Modicon M340, Modicon Quantum, and Modicon Premium legacy systems and their communication modules.
Exploiting CVE-2020-7563 may lead to data corruption, system crashes, or unauthorized code execution on affected devices.
Yes, CVE-2020-7563 is publicly disclosed and reported in the Common Vulnerabilities and Exposures database.