First published: Wed Apr 29 2020(Updated: )
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to alter licenses assigned to the system nodes by sending specially crafted messages to the CLS web service.
Credit: cybersecurity@ch.abb.com
Affected Software | Affected Version | How to fix |
---|---|---|
Abb 800xa System | =5.1 | |
Abb 800xa System | =5.1-feature_pack_4 | |
Abb 800xa System | =5.1-feature_pack_4_revision_d | |
Abb 800xa System | =5.1-revision_a | |
Abb 800xa System | =5.1-revision_b | |
Abb 800xa System | =5.1-revision_c | |
Abb 800xa System | =5.1-revision_d | |
Abb 800xa System | =5.1-revision_e | |
Abb 800xa System | =5.1-revision_e_feature_pack_4 | |
Abb 800xa System | =6.0 | |
Abb 800xa System | =6.0.1 | |
Abb 800xa System | =6.0.3 | |
Abb 800xa System | =6.0.3.3 | |
Abb 800xa System | =6.1 | |
Abb Compact Hmi | =5.1 | |
Abb Compact Hmi | =5.1-feature_pack_4_revision_d | |
Abb Compact Hmi | =5.1-revision_b | |
Abb Compact Hmi | =5.1-revision_d | |
Abb Compact Hmi | =6.0.1-1 | |
Abb Compact Hmi | =6.0.3-2 | |
Abb Control Builder Safe | =1.0 | |
Abb Control Builder Safe | =1.1 | |
Abb Control Builder Safe | =2.0 |
Sign up to SecAlerts for real-time vulnerability data matched to your software, aggregated from hundreds of sources.
The vulnerability ID for this ABB vulnerability is CVE-2020-8476.
The affected software for this vulnerability includes ABB Ability™ System 800xA versions 5.1, 6.0, and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe versions 1.0, 1.1, and 2.0, Symphony Plus -S+ Operations versions 3.0 to 3.2, and Symphony Plus -S+ Engineering versions 1.1 to 2.2.
This vulnerability has a severity rating of 7.5, indicating a high severity.
The Common Weakness Enumeration (CWE) ID for this vulnerability is CWE-20.
To fix this vulnerability, it is recommended to apply the security patches provided by ABB. Please refer to the ABB documentation for specific instructions.