CVE-2021-31371: Junos OS: QFX5000 Series: Traffic from the network internal to the device (128.0.0.0) may be forwarded to egress interfaces.

Published Oct 19, 2021
·
Updated

Juniper Networks Junos OS uses the 128.0.0.0/2 subnet for internal communications between the RE and PFEs. It was discovered that packets utilizing these IP addresses may egress an QFX5000 Series switch, leaking configuration information such as heartbeats, kernel versions, etc. out to the Internet, leading to an information exposure vulnerability. This issue affects Juniper Networks Junos OS on QFX5110, QFX5120, QFX5200, QFX5210 Series, and QFX5100 with QFX 5e Series image installed: All versions prior to 17.3R3-S12; 18.1 versions prior to 18.1R3-S13; 18.3 versions prior to 18.3R3-S5; 19.1 versions prior to 19.1R3-S6; 19.2 versions prior to 19.2R1-S7, 19.2R3-S3; 19.3 versions prior to 19.3R2-S6, 19.3R3-S3; 19.4 versions prior to 19.4R1-S4, 19.4R3-S5; 20.1 versions prior to 20.1R2-S2, 20.1R3-S1; 20.2 versions prior to 20.2R3-S2; 20.3 versions prior to 20.3R3-S1; 20.4 versions prior to 20.4R2-S1, 20.4R3; 21.1 versions prior to 21.1R1-S1, 21.1R2;

Affected Software

150 affected components
Juniper Junos<=17.2
Juniper Junos=17.3
Juniper Junos=17.3-r1
Juniper Junos=17.3-r1-s1
Juniper Junos=17.3-r1-s4
Juniper Junos=17.3-r2
Juniper Junos=17.3-r2-s1
Juniper Junos=17.3-r2-s2
Juniper Junos=17.3-r2-s3
Juniper Junos=17.3-r2-s4
Juniper Junos=17.3-r2-s5
Juniper Junos=17.3-r3
Juniper Junos=17.3-r3-s1
Juniper Junos=17.3-r3-s10
Juniper Junos=17.3-r3-s11
Juniper Junos=17.3-r3-s2
Juniper Junos=17.3-r3-s3
Juniper Junos=17.3-r3-s4
Juniper Junos=17.3-r3-s5
Juniper Junos=17.3-r3-s6
Juniper Junos=17.3-r3-s7
Juniper Junos=17.3-r3-s8
Juniper Junos=17.3-r3-s9
Juniper Junos=18.1
Juniper Junos=18.1-r1
Juniper Junos=18.1-r2
Juniper Junos=18.1-r2-s1
Juniper Junos=18.1-r2-s2
Juniper Junos=18.1-r2-s4
Juniper Junos=18.1-r3
Juniper Junos=18.1-r3-s1
Juniper Junos=18.1-r3-s10
Juniper Junos=18.1-r3-s11
Juniper Junos=18.1-r3-s12
Juniper Junos=18.1-r3-s2
Juniper Junos=18.1-r3-s3
Juniper Junos=18.1-r3-s4
Juniper Junos=18.1-r3-s5
Juniper Junos=18.1-r3-s6
Juniper Junos=18.1-r3-s7
Juniper Junos=18.1-r3-s8
Juniper Junos=18.1-r3-s9
Juniper Junos=18.3
Juniper Junos=18.3-r1
Juniper Junos=18.3-r1-s1
Juniper Junos=18.3-r1-s2
Juniper Junos=18.3-r1-s3
Juniper Junos=18.3-r1-s4
Juniper Junos=18.3-r1-s5
Juniper Junos=18.3-r1-s6
Juniper Junos=18.3-r2
Juniper Junos=18.3-r2-s1
Juniper Junos=18.3-r2-s2
Juniper Junos=18.3-r2-s3
Juniper Junos=18.3-r2-s4
Juniper Junos=18.3-r3
Juniper Junos=18.3-r3-s1
Juniper Junos=18.3-r3-s2
Juniper Junos=18.3-r3-s3
Juniper Junos=18.3-r3-s4
Juniper Junos=19.1
Juniper Junos=19.1-r1
Juniper Junos=19.1-r1-s1
Juniper Junos=19.1-r1-s2
Juniper Junos=19.1-r1-s3
Juniper Junos=19.1-r1-s4
Juniper Junos=19.1-r1-s5
Juniper Junos=19.1-r1-s6
Juniper Junos=19.1-r2
Juniper Junos=19.1-r2-s1
Juniper Junos=19.1-r2-s2
Juniper Junos=19.1-r2-s3
Juniper Junos=19.1-r3
Juniper Junos=19.1-r3-s1
Juniper Junos=19.1-r3-s2
Juniper Junos=19.1-r3-s3
Juniper Junos=19.1-r3-s4
Juniper Junos=19.1-r3-s5
Juniper Junos=19.2
Juniper Junos=19.2-r1
Juniper Junos=19.2-r1-s1
Juniper Junos=19.2-r1-s2
Juniper Junos=19.2-r1-s3
Juniper Junos=19.2-r1-s4
Juniper Junos=19.2-r1-s5
Juniper Junos=19.2-r1-s6
Juniper Junos=19.2-r2
Juniper Junos=19.2-r2-s1
Juniper Junos=19.2-r3
Juniper Junos=19.2-r3-s1
Juniper Junos=19.2-r3-s2
Juniper Junos=19.3
Juniper Junos=19.3-r1
Juniper Junos=19.3-r1-s1
Juniper Junos=19.3-r2
Juniper Junos=19.3-r2-s1
Juniper Junos=19.3-r2-s2
Juniper Junos=19.3-r2-s3
Juniper Junos=19.3-r2-s4
Juniper Junos=19.3-r2-s5
Juniper Junos=19.3-r3
Juniper Junos=19.3-r3-s1
Juniper Junos=19.3-r3-s2
Juniper Junos=19.4-r1
Juniper Junos=19.4-r1-s1
Juniper Junos=19.4-r1-s2
Juniper Junos=19.4-r1-s3
Juniper Junos=19.4-r2
Juniper Junos=19.4-r2-s1
Juniper Junos=19.4-r2-s2
Juniper Junos=19.4-r2-s3
Juniper Junos=19.4-r2-s4
Juniper Junos=19.4-r2-s5
Juniper Junos=19.4-r3
Juniper Junos=19.4-r3-s1
Juniper Junos=19.4-r3-s2
Juniper Junos=19.4-r3-s3
Juniper Junos=19.4-r3-s4
Juniper Junos=20.1-r1
Juniper Junos=20.1-r1-s1
Juniper Junos=20.1-r1-s2
Juniper Junos=20.1-r1-s3
Juniper Junos=20.1-r1-s4
Juniper Junos=20.1-r2
Juniper Junos=20.1-r2-s1
Juniper Junos=20.1-r3
Juniper Junos=20.2-r1
Juniper Junos=20.2-r1-s1
Juniper Junos=20.2-r1-s2
Juniper Junos=20.2-r1-s3
Juniper Junos=20.2-r2
Juniper Junos=20.2-r2-s1
Juniper Junos=20.2-r2-s2
Juniper Junos=20.2-r2-s3
Juniper Junos=20.2-r3
Juniper Junos=20.2-r3-s1
Juniper Junos=20.3-r1
Juniper Junos=20.3-r1-s1
Juniper Junos=20.3-r2
Juniper Junos=20.3-r2-s1
Juniper Junos=20.3-r3
Juniper Junos=20.4-r1
Juniper Junos=20.4-r1-s1
Juniper Junos=20.4-r2
Juniper Junos=21.1-r1
Juniper QFX5100
Juniper QFX5110
Juniper QFX5120
Juniper QFX5200
Juniper QFX5210

Remediation

Information

The following software releases have been updated to resolve this specific issue: 17.3R3-S12, 18.1R3-S13, 18.3R3-S5, 19.1R3-S6, 19.2R1-S7, 19.2R3-S3, 19.3R2-S6, 19.3R3-S3, 19.4R1-S4, 19.4R3-S5, 20.1R2-S2, 20.1R3-S1, 20.2R3-S2, 20.3R3-S1, 20.4R2-S1, 20.4R3, 21.1R1-S1, 21.1R2, 21.2R1, and all subsequent releases.

Event History

Oct 19, 2021
CVE Published
via MITRE·06:17 PM
Data Sourced
via MITRE·06:17 PM
RemedyDescriptionSeverityWeakness
Free Weekly Intel

Don't miss critical vulnerabilities

Join thousands of security professionals who receive our weekly digest of trending CVEs, zero-days, and exploited vulnerabilities.

No spam. Unsubscribe anytime.

Frequently Asked Questions

1

What is the severity of CVE-2021-31371?

CVE-2021-31371 has a high severity rating due to the potential exposure of sensitive configuration information.

2

How do I fix CVE-2021-31371?

To remediate CVE-2021-31371, upgrade to a fixed version of Junos OS that mitigates this vulnerability.

3

Which versions of Junos OS are affected by CVE-2021-31371?

Junos OS versions prior to 17.3 and versions including 17.3, 18.1, and 19.1 are affected by CVE-2021-31371.

4

What type of exposure does CVE-2021-31371 involve?

CVE-2021-31371 can lead to the unintentional egress of packets carrying internal configuration data.

5

Is my hardware affected by CVE-2021-31371 if I use QFX5000 Series switches?

Yes, if using QFX5000 Series switches with affected Junos OS versions, they are susceptible to CVE-2021-31371.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203