AVEVA System Platform versions 2017 through 2020 R2 P01 does not verify, or incorrectly verifies, the cryptographic signature for data.

Affected Software

5 affected components
AVEVA Software, LLC AVEVA reports the vulnerability affects AVEVA System Platform versions 2017 through 2020 R2 P01 (inclusive)
AVEVA System Platform>=2017<2020
AVEVA System Platform=2020
AVEVA System Platform=2020-r2
AVEVA System Platform=2020-r2_p01

Remediation

Information

AVEVA recommends organizations evaluate the impact of these vulnerabilities based on their operational environment, architecture, and product implementation. AutoBuild service is intended to be used only on the GR Node of System Platform during configuration. If the AutoBuild service is enabled on any Runtime nodes, it should be disabled. Furthermore, if the AutoBuild functionality is not used on the GR Node, the AutoBuild service can be disabled on the GR Node as an alternative mitigation that does not require patching. AVEVA recommends users who need to continually use the AutoBuild functionality and cannot disable it in System Platform Versions 2017 through 2020 R2 P01 (inclusive) are affected by the vulnerabilities and should first upgrade to one of the System Platform versions listed below, then apply the corresponding security update: System Platform 2020 R2 P01, 2020 R2, 2020: Apply AVEVA Communication Drivers Pack 2020 R2.1 System Platform 2017 U3 SP1 P01: First apply AVEVA Communication Drivers Pack 2020 R2 AVEVA notes that Activated Licensing is required to apply AVEVA Communication Drivers Pack 2020 R2 on top of System Platform 2017 U3 SP1 P01. For information on AVEVA license compatibility, please contact AVEVA Customer Support. Then apply AVEVA Communication Drivers Pack 2020 R2.1 Please see AVEVA’s security bulletin AVEVA-2021-002 for more information.

Event History

Apr 4, 2022
CVE Published
via MITRE·07:45 PM
Data Sourced
via MITRE·07:45 PM
RemedyDescriptionSeverityWeakness
Aug 3, 2024
Data Sourced
via ICS·11:42 PM
SeverityWeaknessAffected Software

Parent advisories

This vulnerability appears in the following advisories.

Free Weekly Intel

Don't miss critical vulnerabilities

Join thousands of security professionals who receive our weekly digest of trending CVEs, zero-days, and exploited vulnerabilities.

No spam. Unsubscribe anytime.

Frequently Asked Questions

1

What is CVE-2021-32977?

CVE-2021-32977 is a vulnerability in AVEVA System Platform versions 2017 through 2020 R2 P01 that allows an attacker to bypass the cryptographic signature verification for data.

2

How severe is CVE-2021-32977?

CVE-2021-32977 has a severity rating of 7.2 (high).

3

Which software versions are affected by CVE-2021-32977?

AVEVA System Platform versions 2017 through 2020 R2 P01 are affected by CVE-2021-32977.

4

How can CVE-2021-32977 be fixed?

To fix CVE-2021-32977, it is recommended to install the relevant security updates provided by AVEVA. Please refer to the official AVEVA security bulletin for further instructions.

5

Where can I find more information about CVE-2021-32977?

You can find more information about CVE-2021-32977 in the AVEVA security bulletin and the CISA advisory linked in the references section.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203