CVE-2022-2003: AutomationDirect DirectLOGIC with Serial Communication Cleartext Transmission
Published Aug 31, 2022
·Updated
AutomationDirect DirectLOGIC is vulnerable to a specifically crafted serial message to the CPU serial port that will cause the PLC to respond with the PLC password in cleartext. This could allow an attacker to access and make unauthorized changes. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to 2.72; D0-06DD2 versions prior to 2.72; D0-06DR versions prior to 2.72; D0-06DA versions prior to 2.72; D0-06AR versions prior to 2.72; D0-06AA versions prior to 2.72; D0-06DD1-D versions prior to 2.72; D0-06DD2-D versions prior to 2.72; D0-06DR-D versions prior to 2.72;
Affected Software
27 affected components
AutomationDirect All versions of H0-ECOM and H0-ECOM100 when installed in the following D0-06 series CPUs versions prior to v2.72:
D0-06DD1
D0-06DD2
D0-06DR
D0-06DA
D0-06AR
D0-06AA
D0-06DD1-D
D0-06DD2-D
D0-06DR-D
AutomationDirect D0-06DD1
AutomationDirect D0-06DD2
AutomationDirect D0-06DR
AutomationDirect D0-06DA
AutomationDirect D0-06DD1-D
AutomationDirect D0-06DD2-D
AutomationDirect D0-06DR-D
AutomationDirect The following D0-06 series CPUs, prior to v2.72:
D0-06DD1
D0-06DD2
D0-06DR
D0-06DA
D0-06AR
D0-06AA
D0-06DD1-D
D0-06DD2-D
D0-06DR-D
D0-06DD2-D
D0-06DR-D
AutomationDirect D0-06dd1 Firmware<2.72
AutomationDirect D0-06DD1
AutomationDirect D0-06dd2 Firmware<2.72
AutomationDirect D0-06DD2
AutomationDirect D0-06dr Firmware<2.72
AutomationDirect D0-06DR
AutomationDirect D0-06da Firmware<2.72
AutomationDirect D0-06DA
AutomationDirect D0-06ar Firmware<2.72
AutomationDirect D0-06AR
AutomationDirect D0-06aa Firmware<2.72
AutomationDirect D0-06AA
AutomationDirect D0-06dd1-d Firmware<2.72
AutomationDirect D0-06DD1-D
AutomationDirect D0-06dd2-d Firmware<2.72
AutomationDirect D0-06DD2-D
AutomationDirect D0-06dr-d Firmware<2.72
AutomationDirect D0-06DR-D
Remediation
Patch Available
Patch Available
Information
AutomationDirect recommends users upgrade to firmware Version 2.72 or later, which will no longer respond with the password when requested with the specially crafted message.
Additional mitigation for brute force password access has also been added. Three incorrect password entries will result in a 3-hour lock out of password entry. Power cycle will allow subsequent password attempts.
While automation networks and systems have built-in password protection schemes, this is only one step in securing the affected systems. Automation control system networks must incorporate data protection and security measures at least as robust as a typical business computer system. AutomationDirect recommends users of PLCs, HMI products, and other SCADA system products perform independent network security analysis to determine the proper level of security required for the application.
AutomationDirect has identified the specific mitigation actions listed below:
Secure physical access.
Isolate and air gap networks when possible.
Consider some of the AutomationDirect newer PLC families.