CVE-2023-0776: Remote Code Execution in Baicells QRTB Platform

Published Feb 10, 2023
·
Updated

Baicells Nova 436Q, Nova 430E, Nova 430I, and Neutrino 430 LTE TDD eNodeB devices with firmware through QRTB 2.12.7 are vulnerable to remote shell code exploitation via HTTP command injections. Commands are executed using pre-login execution and executed with root permissions. The following methods below have been tested and validated by a 3rd party analyst and has been confirmed exploitable special thanks to Rustam Amin for providing the steps to reproduce.

Affected Software

8 affected components
Baicells Neutrino 430 Firmware<=qrtb_2.12.7
Baicells Neutrino 430
Baicells Nova430l Firmware<=qrtb_2.12.7
Baicells Nova430l
Baicells Nova430e Firmware<=qrtb_2.12.7
Baicells Nova430e
Baicells Nova436q Firmware<=qrtb_2.12.7
Baicells Nova436Q

Remediation

Information

Baicells recommends that all customers currently running an earlier version of QRTB upgrades their products to the 2.12.8 firmware.

Event History

Feb 10, 2023
CVE Published
via MITRE·09:50 PM
Data Sourced
via MITRE·09:50 PM
RemedyDescriptionSeverityWeakness
Free Weekly Intel

Don't miss critical vulnerabilities

Join thousands of security professionals who receive our weekly digest of trending CVEs, zero-days, and exploited vulnerabilities.

No spam. Unsubscribe anytime.

Frequently Asked Questions

1

What is the vulnerability ID for this vulnerability?

The vulnerability ID for this vulnerability is CVE-2023-0776.

2

Which Baicells devices are affected by this vulnerability?

Baicells Nova 436Q, Nova 430E, Nova 430I, and Neutrino 430 LTE TDD eNodeB devices are affected by this vulnerability.

3

What is the severity level of vulnerability CVE-2023-0776?

The severity level of vulnerability CVE-2023-0776 is critical.

4

How can the vulnerability be exploited?

The vulnerability can be exploited through remote shell code exploitation via HTTP command injections.

5

How can the vulnerability be fixed?

To fix the vulnerability, it is recommended to update the firmware of the Baicells devices to QRTB 2.12.7 or later.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.