First published: Tue Nov 14 2023(Updated: )
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.0), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.0), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.0), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.0), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V2.4.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V2.4.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V2.4.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V2.4.0), SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0) (All versions < V2.4.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V2.4.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V2.4.0), SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0) (All versions < V2.4.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V2.4.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V2.4.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V2.4.0), SCALANCE WUB762-1 (6GK5762-1AJ00-2AA0) (All versions < V2.4.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V2.4.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V2.4.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V2.4.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V2.4.0), SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0) (All versions < V2.4.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V2.4.0), SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0) (All versions < V2.4.0). Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. Follow-up of CVE-2022-36323.
Credit: productcert@siemens.com
Affected Software | Affected Version | How to fix |
---|---|---|
All of | ||
Siemens 6GK5205-3BB00-2AB2 | <4.5 | |
Siemens 6GK5205-3BB00-2AB2 Firmware | ||
All of | ||
Siemens 6GK5205-3BB00-2TB2 | <4.5 | |
Siemens 6GK5205-3BB00-2TB2 Firmware | ||
All of | ||
Siemens 6GK5205-3BD00-2TB2 | <4.5 | |
Siemens 6GK5205-3BD00-2TB2 Firmware | ||
All of | ||
Siemens 6GK5205-3BD00-2AB2 | <4.5 | |
Siemens 6GK5205-3BD00-2AB2 Firmware | ||
All of | ||
Siemens 6GK5205-3BF00-2TB2 | <=4.5 | |
Siemens 6GK5205-3BF00-2TB2 Firmware | ||
All of | ||
Siemens 6GK5205-3BF00-2AB2 | <4.5 | |
Siemens 6GK5205-3BF00-2AB2 Firmware | ||
All of | ||
Siemens 6GK5208-0BA00-2TB2 Firmware | <4.5 | |
Siemens 6GK5208-0BA00-2TB2 Firmware | ||
All of | ||
Siemens 6GK5208 Firmware | <4.5 | |
Siemens 6GK5208-0BA00-2AB2 Firmware | ||
All of | ||
Siemens 6GK5213-3BD00 | <4.5 | |
Siemens 6GK5213-3BD00-2TB2 Firmware | ||
All of | ||
Siemens 6GK5213-3BD00-2AB2 | <4.5 | |
Siemens 6GK5213-3BD00 | ||
All of | ||
Siemens 6GK5213-3BB00-2TB2 | <4.5 | |
Siemens 6GK5213-3BB00-2TB2 Firmware | ||
All of | ||
Siemens 6GK5213-3BB00-2AB2 | <4.5 | |
Siemens 6GK5213-3BB00-2AB2 Firmware | ||
All of | ||
Siemens 6GK5213-3BB00-2TB2 | <4.5 | |
Siemens 6GK5213-3BF00-2TB2 Firmware | ||
All of | ||
Siemens 6GK5213-3BF00-2AB2 | <4.5 | |
Siemens 6GK5213-3BF00-2AB2 Firmware | ||
All of | ||
Siemens 6GK5216-0BA00-2TB2 | <4.5 | |
Siemens 6GK5216-0BA00-2TB2 Firmware | ||
All of | ||
Siemens 6GK5216-0BA00 Firmware | <4.5 | |
Siemens 6GK5216-0BA00-2AB2 Firmware | ||
All of | ||
Siemens 6GK5206-2BD00-2AC2 | <4.5 | |
Siemens 6GK5206-2BD00-2AC2 Firmware | ||
All of | ||
Siemens 6GK5206-2BB00-2AC2 Firmware | <4.5 | |
Siemens 6GK5206-2BB00-2AC2 Firmware | ||
All of | ||
Siemens 6GK5206-2RS00-2AC2 Firmware | <4.5 | |
Siemens 6GK5206-2RS00-2AC2 Firmware | ||
All of | ||
Siemens 6GK5206-2RS00-5FC2 | <4.5 | |
Siemens 6GK5206-2RS00-5FC2 | ||
All of | ||
Siemens 6GK5206-2RS00-5FC2 | <4.5 | |
Siemens 6GK5206-2RS00-5FC2 Firmware | ||
All of | ||
Siemens 6GK5206-2BS00-2AC2 | <4.5 | |
Siemens 6GK5206-2BS00-2AC2 | ||
All of | ||
Siemens 6GK5206-2BS00-2FC2 | <4.5 | |
Siemens 6GK5206-2BS00-2FC2 Firmware | ||
All of | ||
Siemens 6GK5206-2GS00-2AC2 Firmware | <4.5 | |
Siemens 6GK5206-2GS00-2AC2 Firmware | ||
All of | ||
Siemens 6GK5206-2GS00-2TC2 | <4.5 | |
Siemens 6GK5206-2GS00-2TC2 Firmware | ||
All of | ||
Siemens 6GK5206-2GS00-2FC2 | <4.5 | |
Siemens 6GK5206-2GS00-2FC2 Firmware | ||
All of | ||
Siemens 6GK5208 Firmware | <4.5 | |
Siemens 6GK5208-0BA00-2AC2 | ||
All of | ||
Siemens 6GK5208 Firmware | <4.5 | |
Siemens 6GK5208-0BA00-2FC2 Firmware | ||
All of | ||
Siemens 6GK5208-0GA00-2AC2 | <4.5 | |
Siemens 6GK5208-0GA00-2AC2 | ||
All of | ||
Siemens 6GK5208-0GA00-2TC2 | <4.5 | |
Siemens 6GK5208-0GA00-2TC2 Firmware | ||
All of | ||
Siemens 6GK5208 Firmware | <4.5 | |
Siemens 6GK5208-0GA00-2FC2 Firmware | ||
All of | ||
Siemens 6GK5208 Firmware | <4.5 | |
Siemens 6GK5208-0RA00-2AC2 Firmware | ||
All of | ||
Siemens 6GK5208 Firmware | <4.5 | |
Siemens 6GK5208-0RA00-5AC2 Firmware | ||
All of | ||
Siemens 6GK5216-0BA00-2AC2 | <4.5 | |
Siemens 6GK5216-0BA00-2AC2 Firmware | ||
All of | ||
Siemens 6GK5216 Firmware | <4.5 | |
Siemens 6GK5216-3RS00-2AC2 Firmware | ||
All of | ||
Siemens 6GK5216-3RS00-5AC2 | <4.5 | |
Siemens 6GK5216-3RS00-5AC2 Firmware | ||
All of | ||
Siemens 6GK5216-4BS00-2AC2 Firmware | <4.5 | |
siemens 6gk5216-4bs00-2ac2 firmware | ||
All of | ||
Siemens 6GK5216-4GS00-2AC2 | <4.5 | |
Siemens 6GK5216-4GS00-2AC2 Firmware | ||
All of | ||
Siemens 6GK5216-4GS00-2TC2 | <4.5 | |
Siemens 6GK5216-4GS00-2TC2 Firmware | ||
All of | ||
Siemens 6GK5216-4GS00-2FC2 | <4.5 | |
Siemens 6GK5216-4GS00-2FC2 Firmware | ||
All of | ||
Siemens 6GK5216-0BA00-2FC2 | <4.5 | |
Siemens 6GK5216-0BA00-2FC2 Firmware | ||
All of | ||
Siemens 6GK5224-0BA00-2AC2 Firmware | ||
Siemens 6GK5224-0BA00-2AC2 | <4.5 | |
All of | ||
Siemens 6GK5224-4GS00-2AC2 Firmware | ||
Siemens 6GK5224-4GS00-2AC2 | <4.5 | |
All of | ||
Siemens 6GK5224-4GS00-2TC2 Firmware | ||
Siemens 6GK5224-4GS00-2AC2 | <4.5 | |
All of | ||
Siemens 6GK5224-4GS00-2FC2 Firmware | ||
Siemens 6GK5224-4GS00-2FC2 | <4.5 | |
All of | ||
Siemens 6GK5204-0BA00 | ||
Siemens 6GK5204-0BA00-2GF2 | <4.5 | |
All of | ||
Siemens 6GK5204-2AA00-2YF2 Firmware | ||
Siemens 6GK5204-2AA00-2YF2 Firmware | <4.5 | |
All of | ||
Siemens 6GK5204 | ||
Siemens 6GK5204-2AA00-2GF2 | <4.5 | |
All of | ||
Siemens 6GK5204 | ||
Siemens 6GK5204-2AA00-2YF2 | <4.5 | |
All of | ||
Siemens 6GK5208-0HA00-2AS6 Firmware | ||
Siemens 6GK5208-0HA00-2AS6 Firmware | <4.5 | |
All of | ||
Siemens 6GK5208-0HA00-2TS6 | <4.5 | |
Siemens 6GK5208-0HA00-2TS6 Firmware | ||
All of | ||
Siemens 6GK5208-0HA00-2ES6 Firmware | <4.5 | |
Siemens 6GK5208-0HA00-2ES6 Firmware | ||
All of | ||
Siemens 6GK5208-0UA00-5ES6 | <4.5 | |
Siemens 6GK5208-0UA00-5ES6 Firmware | ||
All of | ||
Siemens 6GK5216 Firmware | <4.5 | |
Siemens 6GK5216-0HA00-2AS6 Firmware | ||
All of | ||
Siemens 6GK5216-0HA00-2TS6 | <4.5 | |
Siemens 6GK5216-0HA00 | ||
All of | ||
Siemens 6GK5216-0HA00-2AS6 | <4.5 | |
Siemens 6GK5216-0HA00-2ES6 Firmware | ||
All of | ||
Siemens 6GK5216-0UA00-5ES6 | <4.5 | |
Siemens 6GK5216-0UA00-5ES6 Firmware | ||
All of | ||
Siemens 6GK5324-0BA00-3AR3 | <4.5 | |
Siemens 6GK5324-0BA00-3AR3 Firmware | ||
All of | ||
Siemens 6GK5324-0BA00-2AR3 | <4.5 | |
Siemens 6GK5324-0BA00-2AR3 Firmware | ||
All of | ||
Siemens 6GK5326-2QS00-3AR3 Firmware | <4.5 | |
siemens 6gk5326-2qs00-3ar3 firmware | ||
All of | ||
Siemens 6GK5326-2QS00-3RR3 | <4.5 | |
Siemens 6GK5326-2QS00-3RR3 Firmware | ||
All of | ||
Siemens 6GK5328-4FS00-3AR3 | <4.5 | |
Siemens 6GK5328-4FS00-3AR3 | ||
All of | ||
Siemens 6GK5328-4FS00-3RR3 | <4.5 | |
Siemens 6GK5328-4FS00-3RR3 Firmware | ||
All of | ||
Siemens 6GK5328-4FS00-2AR3 | <4.5 | |
Siemens 6GK5328-4FS00-2AR3 Firmware | ||
All of | ||
Siemens 6GK5328-4FS00-2RR3 | <4.5 | |
Siemens 6GK5328-4FS00-2RR3 Firmware | ||
All of | ||
Siemens 6GK5328-4SS00-3AR3 | <4.5 | |
Siemens 6GK5328-4SS00-3AR3 Firmware | ||
All of | ||
Siemens 6GK5328-4SS00-2AR3 | <4.5 | |
Siemens Industrial Ethernet Switch | ||
All of | ||
Siemens 6AG1206-2BB00-7AC2 | <4.5 | |
Siemens 6AG1206-2BB00-7AC2 | ||
All of | ||
Siemens 6AG1206-2BS00-7AC2 | <4.5 | |
Siemens 6AG1206-2BS00-7AC2 Firmware | ||
All of | ||
Siemens 6AG1208-0BA00-7AC2 Firmware | ||
Siemens 6AG1208-0BA00-7AC2 | <4.5 | |
All of | ||
Siemens 6AG1216-4BS00-7AC2 Firmware | ||
Siemens 6AG1216-4BS00-7AC2 | <4.5 |
Sign up to SecAlerts for real-time vulnerability data matched to your software, aggregated from hundreds of sources.
CVE-2023-44373 has a high severity due to the potential impact on device security.
To fix CVE-2023-44373, upgrade to a version of the affected devices that is at least V8.0 or higher.
CVE-2023-44373 affects RUGGEDCOM RM1224 LTE devices and SCALANCE M series routers running firmware versions below V8.0.
The impact of CVE-2023-44373 can lead to unauthorized access or disruption of device functionality.
CVE-2023-44373 was disclosed on October 3, 2023, by Siemens.