CVE-2024-47508: Junos OS Evolved: Specific low privileged CLI commands and SNMP GET requests can trigger a resource leak #2
An Allocation of Resources Without Limits or Throttling vulnerability in the PFE management daemon (evo-pfemand) of Juniper Networks Junos OS Evolved allows an authenticated, network-based attacker to cause an FPC crash leading to a Denial of Service (DoS).When specific SNMP GET operations or specific low-priviledged CLI commands are executed, a GUID resource leak will occur, eventually leading to exhaustion and resulting in FPCs to hang. Affected FPCs need to be manually restarted to recover.
GUID exhaustion will trigger a syslog message like one of the following:
evo-pfemand[<pid>]: getnextguid: Ran out of Guid Space ... evo-aftmand-zx[<pid>]: getnextguid: Ran out of Guid Space ... The leak can be monitored by running the following command and taking note of the values in the rightmost column labeled Guids:
user@host> show platform application-info allocations app evo-pfemand/evo-pfemand
In case one or more of these values are constantly increasing the leak is happening.
This issue affects Junos OS Evolved:
All versions before 21.2R3-S8-EVO, 21.3 versions before 21.3R3-EVO; 21.4 versions before 22.1R2-EVO,
22.1 versions before 22.1R1-S1-EVO, 22.1R2-EVO.
Please note that this issue is similar to, but different from CVE-2024-47505 and CVE-2024-47509.
Affected Software
Remediation
Information
Event History
Frequently Asked Questions
What is the severity of CVE-2024-47508?
CVE-2024-47508 is considered a critical vulnerability that can lead to Denial of Service (DoS) due to resource allocation issues.
How do I fix CVE-2024-47508?
To mitigate CVE-2024-47508, update Junos OS Evolved to the latest patched version that addresses this vulnerability.
Who is affected by CVE-2024-47508?
CVE-2024-47508 affects Juniper Networks Junos OS Evolved versions prior to specific patched releases.
What kind of attack can exploit CVE-2024-47508?
An authenticated, network-based attacker can exploit CVE-2024-47508 to cause an FPC crash leading to a Denial of Service.
What components are involved in CVE-2024-47508?
CVE-2024-47508 involves the PFE management daemon (evo-pfemand) component of Juniper Networks Junos OS Evolved.