CVE-2024-54017: Medium severity Siemens SIPROTEC 5 6MD84 (CP300) vulnerability

Published May 12, 2026
·
Updated

A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V11.0), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SA82 (CP100) (All versions >= V7.80), SIPROTEC 5 7SA82 (CP150) (All versions < V11.0), SIPROTEC 5 7SA84 (CP200) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SD82 (CP100) (All versions >= V7.80), SIPROTEC 5 7SD82 (CP150) (All versions < V11.0), SIPROTEC 5 7SD84 (CP200) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SJ81 (CP100) (All versions >= V7.80), SIPROTEC 5 7SJ81 (CP150) (All versions < V11.0), SIPROTEC 5 7SJ82 (CP100) (All versions >= V7.80), SIPROTEC 5 7SJ82 (CP150) (All versions < V11.0), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SK82 (CP100) (All versions >= V7.80), SIPROTEC 5 7SK82 (CP150) (All versions < V11.0), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SL82 (CP100) (All versions >= V7.80), SIPROTEC 5 7SL82 (CP150) (All versions < V11.0), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7ST86 (CP300) (All versions < V11.0), SIPROTEC 5 7SX82 (CP150) (All versions < V11.0), SIPROTEC 5 7SX85 (CP300) (All versions < V11.0), SIPROTEC 5 7SY82 (CP150) (All versions < V11.0), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7UT82 (CP100) (All versions >= V7.80), SIPROTEC 5 7UT82 (CP150) (All versions < V11.0), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7VU85 (CP300) (All versions < V11.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V11.0). Affected devices do not use sufficiently random values to create session identifiers. This could allow an unauthenticated remote attacker to brute force a session identifier and gain read access to limited information from the web server without authorization.

Affected Software

63 affected components
Siemens SIPROTEC 5 6MD84 (CP300)<11.0
Siemens SIPROTEC 5 6MD85 (CP200)>=undefined
Siemens SIPROTEC 5 6MD85 (CP300)>=7.80<11.0
Siemens SIPROTEC 5 6MD86 (CP200)>=undefined
Siemens SIPROTEC 5 6MD86 (CP300)>=7.80<11.0
Siemens SIPROTEC 5 6MD89 (CP300)>=7.80<11.0
Siemens SIPROTEC 5 6MU85 (CP300)>=7.80<11.0
Siemens SIPROTEC 5 7KE85 (CP200)>=undefined
Siemens SIPROTEC 5 7KE85 (CP300)>=7.80<11.0
Siemens SIPROTEC 5 7SA82 (CP100)>=7.80
Siemens SIPROTEC 5 7SA82 (CP150)<11.0
Siemens SIPROTEC 5 7SA84 (CP200)>=undefined
Siemens SIPROTEC 5 7SA86 (CP200)>=undefined
Siemens SIPROTEC 5 7SA86 (CP300)>=7.80<11.0
Siemens SIPROTEC 5 7SA87 (CP200)>=undefined
Siemens SIPROTEC 5 7SA87 (CP300)>=7.80<11.0
Siemens SIPROTEC 5 7SD82 (CP100)>=7.80
Siemens SIPROTEC 5 7SD82 (CP150)<11.0
Siemens SIPROTEC 5 7SD84 (CP200)>=undefined
Siemens SIPROTEC 5 7SD86 (CP200)>=undefined
Siemens SIPROTEC 5 7SD86 (CP300)>=7.80<11.0
Siemens SIPROTEC 5 7SD87 (CP200)>=undefined
Siemens SIPROTEC 5 7SD87 (CP300)>=7.80<11.0
Siemens SIPROTEC 5 7SJ81 (CP100)>=7.80
Siemens SIPROTEC 5 7SJ81 (CP150)<11.0
Siemens SIPROTEC 5 7SJ82 (CP100)>=7.80
Siemens SIPROTEC 5 7SJ82 (CP150)<11.0
Siemens SIPROTEC 5 7SJ85 (CP200)>=undefined
Siemens SIPROTEC 5 7SJ85 (CP300)>=7.80<11.0
Siemens SIPROTEC 5 7SJ86 (CP200)>=undefined
Siemens SIPROTEC 5 7SJ86 (CP300)>=7.80<11.0
Siemens SIPROTEC 5 7SK82 (CP100)>=7.80
Siemens SIPROTEC 5 7SK82 (CP150)<11.0
Siemens SIPROTEC 5 7SK85 (CP200)>=undefined
Siemens SIPROTEC 5 7SK85 (CP300)>=7.80<11.0
Siemens SIPROTEC 5 7SL82 (CP100)>=7.80
Siemens SIPROTEC 5 7SL82 (CP150)<11.0
Siemens SIPROTEC 5 7SL86 (CP200)>=undefined
Siemens SIPROTEC 5 7SL86 (CP300)>=7.80<11.0
Siemens SIPROTEC 5 7SL87 (CP200)>=undefined
Siemens SIPROTEC 5 7SL87 (CP300)>=7.80<11.0
Siemens SIPROTEC 5 7SS85 (CP200)>=undefined
Siemens SIPROTEC 5 7SS85 (CP300)>=7.80<11.0
Siemens SIPROTEC 5 7ST85 (CP200)>=undefined
Siemens SIPROTEC 5 7ST85 (CP300)>=7.80<11.0
Siemens SIPROTEC 5 7ST86 (CP300)<11.0
Siemens SIPROTEC 5 7SX82 (CP150)<11.0
Siemens SIPROTEC 5 7SX85 (CP300)<11.0
Siemens SIPROTEC 5 7SY82 (CP150)<11.0
Siemens SIPROTEC 5 7UM85 (CP300)>=7.80<11.0
Siemens SIPROTEC 5 7UT82 (CP100)>=7.80
Siemens SIPROTEC 5 7UT82 (CP150)<11.0
Siemens SIPROTEC 5 7UT85 (CP200)>=undefined
Siemens SIPROTEC 5 7UT85 (CP300)>=7.80<11.0
Siemens SIPROTEC 5 7UT86 (CP200)>=undefined
Siemens SIPROTEC 5 7UT86 (CP300)>=7.80<11.0
Siemens SIPROTEC 5 7UT87 (CP200)>=undefined
Siemens SIPROTEC 5 7UT87 (CP300)>=7.80<11.0
Siemens SIPROTEC 5 7VE85 (CP300)>=7.80<11.0
Siemens SIPROTEC 5 7VK87 (CP200)>=undefined
Siemens SIPROTEC 5 7VK87 (CP300)>=7.80<11.0
Siemens SIPROTEC 5 7VU85 (CP300)<11.0
Siemens SIPROTEC 5 Compact 7SX800 (CP050)<11.0

Event History

May 12, 2026
CVE Published
via MITRE·08:20 AM
Data Sourced
via MITRE·08:20 AM
DescriptionSeverityWeakness
Data Sourced
via NVD·10:16 AM
DescriptionSeverityWeakness
Free Weekly Intel

Don't miss critical vulnerabilities

Join thousands of security professionals who receive our weekly digest of trending CVEs, zero-days, and exploited vulnerabilities.

No spam. Unsubscribe anytime.

Frequently Asked Questions

1

What is the severity of CVE-2024-54017?

The severity of CVE-2024-54017 is classified as critical due to its potential impact on device security.

2

How do I fix CVE-2024-54017?

To fix CVE-2024-54017, upgrade the affected Siemens SIPROTEC 5 software to version 11.0 or later.

3

Which versions of Siemens SIPROTEC 5 are affected by CVE-2024-54017?

CVE-2024-54017 affects all versions of Siemens SIPROTEC 5 6MD84, 6MD85, 6MD86, and several others prior to version 11.0.

4

What products are vulnerable under CVE-2024-54017?

Products vulnerable under CVE-2024-54017 include Siemens SIPROTEC 5 6MD84, 6MD85, 6MD86, and various models in the 7 series.

5

What impact does CVE-2024-54017 have on security?

CVE-2024-54017 can lead to unauthorized access and possible manipulation of settings, posing a serious threat to security and operations.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.