CVE-2025-11780: Stack-based buffer overflow vulnreability in Circutor SGE-PLC1000/SGE-PLC50
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'showMeterReport()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the “meter” parameter.
Affected Software
Remediation
Information
Event History
Frequently Asked Questions
What is the severity of CVE-2025-11780?
CVE-2025-11780 is classified as a high severity vulnerability due to the potential for exploitation via stack-based buffer overflow.
How do I fix CVE-2025-11780?
To mitigate CVE-2025-11780, users should update the Circutor SGE-PLC1000 and SGE-PLC50 software to the latest version that addresses this vulnerability.
What systems are affected by CVE-2025-11780?
CVE-2025-11780 affects Circutor SGE-PLC1000 and SGE-PLC50 versions prior to v9.0.2.
What type of vulnerability is CVE-2025-11780?
CVE-2025-11780 is a stack-based buffer overflow vulnerability caused by unchecked user input.
Can CVE-2025-11780 be exploited remotely?
Yes, CVE-2025-11780 can be exploited remotely if an attacker can send crafted input to the affected systems.