CVE-2025-11785: Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50

Published Dec 2, 2025
·
Updated

Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterPasswords()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.

Affected Software

5 affected components
Circutor SGE-PLC1000/SGE-PLC50
All of the following
Circutor SGE-PLC1000 firmware=9.0.2
Circutor SGE-PLC1000
All of the following
Circutor Sge-plc50 Firmware=9.0.2
Circutor SGE-PLC50

Remediation

Information

The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API.

Event History

Dec 2, 2025
CVE Published
via MITRE·01:01 PM
Data Sourced
via MITRE·01:01 PM
RemedyDescriptionWeakness
Data Sourced
via NVD·01:15 PM
DescriptionSeverityWeaknessAffected Software

Frequently Asked Questions

1

What is the severity of CVE-2025-11785?

CVE-2025-11785 is classified as a high severity vulnerability due to the potential for a stack-based buffer overflow that could lead to remote code execution.

2

How do I fix CVE-2025-11785?

To fix CVE-2025-11785, update to the latest version of Circutor SGE-PLC1000/SGE-PLC50 that addresses this vulnerability.

3

What impacts does CVE-2025-11785 have on system security?

CVE-2025-11785 can allow attackers to exploit the buffer overflow to execute arbitrary code, potentially compromising system integrity and confidentiality.

4

Is CVE-2025-11785 present in earlier versions of Circutor SGE-PLC1000/SGE-PLC50?

Yes, CVE-2025-11785 affects Circutor SGE-PLC1000/SGE-PLC50 prior to version 9.0.2 due to the vulnerability in the ShowMeterPasswords() function.

5

What user input is involved in CVE-2025-11785?

CVE-2025-11785 involves user input that is unbounded and copied into a fixed-size buffer, leading to the stack-based buffer overflow.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203