CVE-2025-9362: Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 urlFilterManageRule stack-based overflow

Published Aug 23, 2025
·
Updated

A flaw has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. The impacted element is the function urlFilterManageRule of the file /goform/urlFilterManageRule. Executing manipulation of the argument urlFilterRuleName/scheduleUrl/addURLFilter can lead to stack-based buffer overflow. The attack may be launched remotely. The vendor was contacted early about this disclosure but did not respond in any way.

Affected Software

17 affected components
LinkSys RE6250
LinkSys RE6300
LinkSys RE6500
LinkSys RE7000
LinkSys RE9000
All of the following
LinkSys Re6250 Firmware=1.0.04.001
LinkSys RE6250
All of the following
LinkSys Re6300 Firmware=1.2.07.001
LinkSys RE6300
All of the following
LinkSys Re6350 Firmware=1.0.04.001
LinkSys RE6350
All of the following
LinkSys Re6500 Firmware=1.0.013.001
LinkSys RE6500
All of the following
LinkSys Re7000 Firmware=1.1.05.003
LinkSys RE7000
All of the following
LinkSys Re9000 Firmware=1.0.04.002
LinkSys RE9000

Event History

Aug 23, 2025
CVE Published
via MITRE·01:32 PM
Data Sourced
via MITRE·01:32 PM
DescriptionSeverityWeakness
Data Sourced
via NVD·02:15 PM
DescriptionSeverityWeaknessAffected Software
Feb 28, 57989
Event
via FIRST·05:28 AM
Free Weekly Intel

Don't miss critical vulnerabilities

Join thousands of security professionals who receive our weekly digest of trending CVEs, zero-days, and exploited vulnerabilities.

No spam. Unsubscribe anytime.

Frequently Asked Questions

1

What is the severity of CVE-2025-9362?

CVE-2025-9362 has been classified as a high severity vulnerability affecting multiple Linksys routers.

2

How do I fix CVE-2025-9362?

To mitigate CVE-2025-9362, users should update their Linksys routers to the latest firmware version provided by the manufacturer.

3

What devices are affected by CVE-2025-9362?

CVE-2025-9362 affects the Linksys RE6250, RE6300, RE6350, RE6500, RE7000, and RE9000 models.

4

What is the exploited functionality in CVE-2025-9362?

CVE-2025-9362 exploits the urlFilterManageRule function within the /goform/urlFilterManageRule file.

5

Is CVE-2025-9362 a remote or local vulnerability?

CVE-2025-9362 is considered a remote vulnerability, allowing attackers to manipulate the affected devices without physical access.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203