CVE-2026-102081: Junos OS: SRX4000 Series, SRX5000 Series and MX Series with SPC3: With application services configured, high session churn causes memory leak which will ultimately impact traffic

Published Oct 14, 2026
·
Updated

A Missing Release of Memory after Effective Lifetime vulnerability in the packet forwarding engine (PFE) of Juniper Networks Junos OS on SRX Series allows an unauthenticated, network-based attacker to cause a complete Denial-of-Service (DoS).

On SRX4000 Series, and SRX5000 Series with SPC3, and MX Series with SPC3, when one or more specific application services like ALGs, IDP/DPI, APPID, SECINTEL, AAMW or AppQoE are configured, a high connections per second churn will cause PFE memory to leak. If the memory is exhausted traffic processing will be impacted.

Use the CLI command show security monitoring to monitor the memory utilization of the PFEs on the FPCs.

This issue affects Junos OS on SRX Series and MX Series:

23.4 versions from 23.4R2-S3 before 23.4R2-S7; 24.2 versions from 24.2R2 before 24.2R2-S3; 24.4 versions before 24.4R2-S3; 25.2 versions before 25.2R1-S2, 25.2R2.

Affected Software

1 affected component
Juniper Networks Junos OS>=23.4R2-S3<23.4R2-S7, >=24.2R2<24.2R2-S3, <24.4R2-S3, <25.2R1-S2, =25.2R2

Remediation

Recommended actions to resolve this vulnerability, in priority order.

  1. Upgrade

    Upgrade Juniper Junos OS to a version that resolves this vulnerability.

    Fixed in 23.4R2-S7
  2. Upgrade

    Upgrade Juniper Junos OS to a version that resolves this vulnerability.

    Fixed in 24.2R2-S3
  3. Upgrade

    Upgrade Juniper Junos OS to a version that resolves this vulnerability.

    Fixed in 24.4R2-S3
  4. Upgrade

    Upgrade Juniper Junos OS to a version that resolves this vulnerability.

    Fixed in 25.2R1-S2
  5. Upgrade

    Upgrade Juniper Junos OS to a version that resolves this vulnerability.

    Fixed in 25.2R2
  6. Upgrade

    Upgrade Juniper Junos OS to a version that resolves this vulnerability.

    Fixed in 25.4R1
  7. Compensating control

    Use the CLI command `show security monitoring` to monitor PFE memory utilization on the FPCs.

Event History

Oct 14, 2026
CVE Published
via MITRE·04:26 PM
Data Sourced
via MITRE·04:26 PM
RemedyDescriptionSeverityWeakness

Frequently Asked Questions

1

Which systems are exposed to this issue?

Affected systems are SRX4000 Series, SRX5000 Series with SPC3, and MX Series with SPC3 running an affected Junos OS release. At least one listed application service must be configured, such as ALGs, IDP/DPI, APPID, SECINTEL, AAMW, or AppQoE.

2

Does exploitation require authentication or user interaction?

No. An unauthenticated attacker can trigger the issue remotely by causing high connection-per-second churn.

3

How can I determine whether the issue is affecting a device?

Use the CLI command "show security monitoring" to monitor PFE memory utilization on the FPCs. Increasing or exhausted PFE memory may lead to impaired traffic processing.

4

Which releases contain fixes?

Fixed releases include 23.4R2-S7 or later in the 23.4R2 train, 24.2R2-S3 or later in the 24.2 train, 24.4R2-S3 or later in the 24.4 train, and 25.2R1-S2 or 25.2R2. Affected ranges include releases before those versions as specified.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.