CVE-2026-102177: Junos OS and Junos OS Evolved: An out-of-bounds write causes an rpd crash when IS-IS backup selection is used

Published Oct 14, 2026
·
Updated

An Out-of-bounds Write vulnerability in the routing protocol daemon (rpd) of Juniper Networks Junos OS and Junos OS Evolved allows an adjacent unauthenticated attacker to cause a denial of service when IS-IS link protection and backup-selection are configured.

Affected Software

2 affected components
Juniper Networks Junos OS
Juniper Networks Junos OS Evolved

Remediation

Recommended actions to resolve this vulnerability, in priority order.

  1. Upgrade

    Upgrade Juniper Junos OS Evolved to a version that resolves this vulnerability.

    Fixed in 23.2R2-S7.7-EVO
  2. Upgrade

    Upgrade Juniper Junos OS Evolved to a version that resolves this vulnerability.

    Fixed in 23.4R2-S8.11-EVO
  3. Upgrade

    Upgrade Juniper Junos OS Evolved to a version that resolves this vulnerability.

    Fixed in 24.2R2-S5.6-EVO
  4. Upgrade

    Upgrade Juniper Junos OS Evolved to a version that resolves this vulnerability.

    Fixed in 24.4R2-S5-EVO
  5. Upgrade

    Upgrade Juniper Junos OS Evolved to a version that resolves this vulnerability.

    Fixed in 25.2R2-S2-EVO
  6. Upgrade

    Upgrade Juniper Junos OS Evolved to a version that resolves this vulnerability.

    Fixed in 25.2X100-D35-EVO
  7. Upgrade

    Upgrade Juniper Junos OS Evolved to a version that resolves this vulnerability.

    Fixed in 25.4R1-S3-EVO
  8. Upgrade

    Upgrade Juniper Junos OS Evolved to a version that resolves this vulnerability.

    Fixed in 25.4R2-EVO
  9. Upgrade

    Upgrade Juniper Junos OS Evolved to a version that resolves this vulnerability.

    Fixed in 25.4X300-D40-EVO
  10. Upgrade

    Upgrade Juniper Junos OS Evolved to a version that resolves this vulnerability.

    Fixed in 26.2R1-S2-EVO
  11. Upgrade

    Upgrade Juniper Junos OS Evolved to a version that resolves this vulnerability.

    Fixed in 26.2R2-EVO
  12. Upgrade

    Upgrade Juniper Junos OS Evolved to a version that resolves this vulnerability.

    Fixed in 26.4R1-EVO
  13. Upgrade

    Upgrade Juniper Junos OS to a version that resolves this vulnerability.

    Fixed in 23.2R2-S7.7
  14. Upgrade

    Upgrade Juniper Junos OS to a version that resolves this vulnerability.

    Fixed in 23.4R2-S8.13
  15. Upgrade

    Upgrade Juniper Junos OS to a version that resolves this vulnerability.

    Fixed in 24.2R2-S5.5
  16. Upgrade

    Upgrade Juniper Junos OS to a version that resolves this vulnerability.

    Fixed in 24.4R2-S5
  17. Upgrade

    Upgrade Juniper Junos OS to a version that resolves this vulnerability.

    Fixed in 25.2R2-S2
  18. Upgrade

    Upgrade Juniper Junos OS to a version that resolves this vulnerability.

    Fixed in 25.4R1-S3
  19. Upgrade

    Upgrade Juniper Junos OS to a version that resolves this vulnerability.

    Fixed in 25.4R2
  20. Upgrade

    Upgrade Juniper Junos OS to a version that resolves this vulnerability.

    Fixed in 26.2R1-S2
  21. Upgrade

    Upgrade Juniper Junos OS to a version that resolves this vulnerability.

    Fixed in 26.2R2
  22. Upgrade

    Upgrade Juniper Junos OS to a version that resolves this vulnerability.

    Fixed in 26.4R1

Event History

Oct 14, 2026
CVE Published
via MITRE·04:56 PM
Data Sourced
via MITRE·04:56 PM
RemedyDescriptionSeverityWeakness

Frequently Asked Questions

1

Who is exposed to this issue?

Devices running Junos OS or Junos OS Evolved are exposed when IS-IS link protection and backup-selection are configured. Exploitation requires an attacker adjacent to the affected device; no authentication or user interaction is required.

2

What is the impact of successful exploitation?

An attacker can trigger an out-of-bounds write in the routing protocol daemon (rpd), causing rpd to crash and resulting in a denial of service. The provided severity vector also indicates potential low confidentiality and integrity impact.

3

Are default configurations affected?

The issue is described as requiring both IS-IS link protection and backup-selection to be configured. The provided information does not state whether those features are enabled by default.

4

What can be done if patching cannot happen immediately?

The available information identifies IS-IS link protection and backup-selection as required conditions for exploitation. Review whether both are configured and, where operationally feasible, avoid that affected feature combination until remediation is available.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.