CVE-2026-111735: Integer underflow leads to out-of-bounds read in pf_cpm_c_data_ind()

Published Oct 29, 2026
·
Updated

P-Net before 1.0.3 contains an integer underflow in pfcpmcdataind(). When handling a received cyclic data frame while the consumer is in the FRUN or RUN state, the offset of the APDU status was computed as the frame length minus 4 using 16-bit arithmetic, without checking that the frame is long enough. A crafted short frame makes the offset wrap around, so the function reads outside the receive buffer. This can cause a crash (denial of service) or disclose memory content.

Remediation

Recommended actions to resolve this vulnerability, in priority order.

  1. Upgrade

    Upgrade P-Net to a version that resolves this vulnerability.

    Fixed in 1.0.3

Event History

Oct 29, 2026
CVE Published
via MITRE·03:42 PM
Data Sourced
via MITRE·03:42 PM
RemedyDescriptionWeakness
Data Sourced
via NVD·04:17 PM
DescriptionSeverityWeakness

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.