CVE-2026-123757: Incomplete domain name sanitization during Bind autosecondary zone transfer
An attacker can send a notify request that causes the root zone to be added as a secondary domain to be added to the bind backend, but causes said backend to update its configuration to an invalid one, leading to the backend no longer able to run on the next restart, requiring manual operation to fix it. The general case of this problem was addressed by SA-2026-05, but the root zone was not handled correctly. This is now fixed.
Affected Software
Event History
Frequently Asked Questions
Which deployments should be prioritized for review?
PowerDNS Authoritative Server deployments using the Bind backend and autosecondary zone transfers are the relevant scope indicated by the advisory.
What access does an attacker need to exploit this issue?
An attacker needs network access sufficient to send a notify request. The supplied vector indicates no privileges and no user interaction are required, although exploitation has high attack complexity.