CVE-2026-124758: Integer underflow of the record data length in IODWrite requests

Published Nov 13, 2026
·
Updated

P-Net before 1.0.4 does not check the record data length of an IODWrite request to a non-user record index against the size of the record block header. The 32-bit length is reduced by the header size before it is passed to the record handlers, so a length smaller than the header underflows and the handlers receive a data length of about 65530. The fixed-size reads of the I&M and PDPort handlers can then read past the end of the session buffer. The result of the write is discarded. The attacker must have an established Application Relationship or be able to send in the context of one, and requires ADJACENT network access.

Affected Software

1 affected component
RT-Labs P-Net<1.0.4

Remediation

Recommended actions to resolve this vulnerability, in priority order.

  1. Upgrade

    Upgrade to a fixed release to a version that resolves this vulnerability.

    Fixed in 1.0.4

Event History

Nov 13, 2026
CVE Published
via MITRE·01:23 PM
Data Sourced
via MITRE·01:23 PM
RemedyDescriptionWeakness
Data Sourced
via NVD·02:17 PM
DescriptionSeverityWeakness

Frequently Asked Questions

1

Which deployments are exposed to this issue?

Deployments using P-Net versions before 1.0.4 are affected when they process IODWrite requests to non-user record indexes. Exploitation requires adjacent-network access and an established Application Relationship, or the ability to send requests in the context of one.

2

What is the practical impact of a successful exploit?

A malformed IODWrite request with a record data length smaller than the record block header can cause the I&M and PDPort handlers to read beyond the session buffer. The disclosed impact is limited to availability; the write result is discarded.

3

What request condition triggers the underflow?

The record data length must be smaller than the record block header size on an IODWrite request targeting a non-user record index. Subtracting the header size from the 32-bit length causes it to underflow, passing a length of about 65530 to record handlers.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.