CVE-2026-130777: Incus before 7.6.0 Cross-Project Information Disclosure via OVN ACL Events
Incus before 7.6.0 contains an information disclosure vulnerability that allows project-restricted authenticated clients to receive other projects' OVN ACL logs because these events are broadcast with an empty project. Attackers can subscribe to network-acl events on one accessible project to observe internal IPs, ports, protocols, and allow/drop decisions across all projects.
Affected Software
Remediation
Recommended actions to resolve this vulnerability, in priority order.
- Upgrade
Upgrade
Incusto a version that resolves this vulnerability.Fixed in 7.6.0
Event History
Frequently Asked Questions
Which clients can exploit this issue?
An authenticated client restricted to a project can exploit the issue if it can subscribe to network-acl events on a project it can access. No user interaction is required.
What information could be exposed?
Affected clients may observe OVN ACL logs from other projects, including internal IP addresses, ports, protocols, and allow or drop decisions.
What version should be used to remediate the issue?
Upgrade Incus to version 7.6.0 or later. Versions before 7.6.0 are affected.