CVE-2026-15061: Vulnerabilities in IBM AIX and PowerVM VIOS

Published Aug 15, 2026
·
Updated

AIX's nimesis registration service could allow a remote attacker to overwrite files due to path traversal.

Other sources

IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 's nimesis registration service could allow a remote attacker to overwrite files due to path traversal.

MITRE

Affected Software

3 affected components
IBM AIX<=7.2
IBM AIX<=7.3
IBM PowerVM VIOS<=4.1

Remediation

Recommended actions to resolve this vulnerability, in priority order.

  1. Upgrade

    Upgrade IBM PowerVM VIOS 4.1.0 to a version that resolves this vulnerability.

    Fixed in 4.1.0.50
  2. Upgrade

    Upgrade IBM PowerVM VIOS 4.1.1 to a version that resolves this vulnerability.

    Fixed in 4.1.1.30
  3. Upgrade

    Upgrade IBM PowerVM VIOS 4.1.2 to a version that resolves this vulnerability.

    Fixed in 4.1.2.20
  4. Upgrade

    Upgrade to a fixed release to a version that resolves this vulnerability.

    Patch IJ5956608
  5. Upgrade

    Upgrade to a fixed release to a version that resolves this vulnerability.

    Patch IJ5956508
  6. Upgrade

    Upgrade to a fixed release to a version that resolves this vulnerability.

    Patch IJ5956408
  7. Upgrade

    Upgrade to a fixed release to a version that resolves this vulnerability.

    Patch IJ59563
  8. Upgrade

    Upgrade to a fixed release to a version that resolves this vulnerability.

    Patch IJ5956308
  9. Operational

    To complete the SP/FP update, reboot the LPAR.

  10. Operational

    For VIOS 4.1.0 and VIOS 4.1.1, perform the additional steps to migrate to the latest Postgres15 after applying the 4.1.0.50 or 4.1.1.30 VIOS FPs, respectively.

  11. Operational

    If applying AIX/VIOS patches using nimsh secure, take the special steps required because the protocol between master and client is updated to be more secure.

Event History

Aug 15, 2026
CVE Published
via IBM·12:00 AM
Data Sourced
via IBM·12:00 AM
DescriptionAffected Software
Aug 19, 2026
CVE Published
via MITRE·02:33 PM
Data Sourced
via MITRE·02:33 PM
RemedyDescriptionSeverityWeakness

Parent advisories

This vulnerability appears in the following advisories.

Frequently Asked Questions

1

Which systems are in scope?

IBM AIX 7.2 and 7.3, and IBM PowerVM VIOS 4.1, are identified as affected through the nimesis registration service. The provided information does not state whether the service is enabled by default.

2

What access does an attacker need?

The CVSS vector indicates network-based exploitation with low attack complexity. It requires no privileges and no user interaction.

3

What could successful exploitation do?

A remote attacker could overwrite files through path traversal in the nimesis registration service. The reported impact is high to integrity, low to availability, and none to confidentiality.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203