CVE-2026-16828: Power System Out-of-bounds Read

Published Aug 15, 2026
·
Updated

IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker on the management network can cause the ASMI web server to crash with possible memory corruption and generate an error log; hosted partitions are not affected. The ASMI web interface will restart automatically; however, repeated exploitation could result in a sustained loss of access to the ASMI management interface, resulting in an integrity and availability impact.

Other sources

Power Systems Firmware is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker on the management network can cause the ASMI web server to crash with possible memory corruption and generate an error log; hosted partitions are not affected. The ASMI web interface will restart automatically; however, repeated exploitation could result in a sustained loss of access to the ASMI management interface, resulting in an integrity and availability impact.

IBM

Affected Software

24 affected components
IBM Server Firmware>=950.00<=950.H2, >=1060.00<=1060.80, >=1110.00<=1110.30, =1120.00
IBM Server Firmware<=FW1120.00
IBM Server Firmware<=FW1110.00 - FW1110.30
IBM Server Firmware<=FW1060.00 - FW1060.80
IBM Server Firmware<=FW950.00 - FW950.H2
All of the following
IBM Power System E1080 \(9080-hex\) Firmware>=fw1060.00<fw1060.81
IBM Power System E1080 \(9080-hex\)
All of the following
Any of the following
IBM Power System E1180 \(9080-heu\) Firmware>=fw1110.00<fw1110.31
IBM Power System E1180 \(9080-heu\) Firmware=fw1120.00
IBM Power System E1180 \(9080-heu\)
All of the following
IBM Power System S922 \(9009-22g\) Firmware>=fw950.00<fw950.h3
IBM Power System S922 \(9009-22g\)
All of the following
IBM Power System H922 \(9223-22s\) Firmware>=fw950.00<fw950.h3
IBM Power System H922 \(9223-22s\)
All of the following
IBM Power System S914 \(9009-41g\) Firmware>=fw950.00<fw950.h3
IBM Power System S914 \(9009-41g\)
All of the following
IBM Power System S924 \(9009-42g\) Firmware>=fw950.00<fw950.h3
IBM Power System S924 \(9009-42g\)
All of the following
IBM Power System H924 \(9223-42s\) Firmware>=fw950.00<fw950.h3
IBM Power System H924 \(9223-42s\)
All of the following
IBM Power System E950 \(9040-mr9\) Firmware>=fw950.00<fw950.h3
IBM Power System E950 \(9040-mr9\)
All of the following
IBM Power System E980 \(9080-m9s\) Firmware>=fw950.00<fw950.h3
IBM Power System E980 \(9080-m9s\)

Remediation

Recommended actions to resolve this vulnerability, in priority order.

  1. Upgrade

    Upgrade IBM Power Systems Firmware FW1060.81 (1060_184) or newer to a version that resolves this vulnerability.

    Fixed in FW1060.81(1060_184)
  2. Upgrade

    Upgrade IBM Power Systems Firmware FW1120.01 (1120_167) or newer to a version that resolves this vulnerability.

    Fixed in FW1120.01(1120_167)
  3. Upgrade

    Upgrade IBM Power Systems Firmware FW1110.31 (1110_134) or newer to a version that resolves this vulnerability.

    Fixed in FW1110.31(1110_134)
  4. Upgrade

    Upgrade IBM Power Systems Firmware FW950.H3 (950_230) or newer to a version that resolves this vulnerability.

    Fixed in FW950.H3(950_230)
  5. Compensating control

    Mitigate repeated exploitation impact by restricting access to the ASMI management interface from untrusted networks (allow only trusted management-network sources).

Event History

Aug 15, 2026
CVE Published
via IBM·12:00 AM
Data Sourced
via IBM·12:00 AM
DescriptionAffected Software
Aug 19, 2026
CVE Published
via MITRE·06:43 PM
Data Sourced
via MITRE·06:43 PM
RemedyDescriptionSeverityWeakness
Data Sourced
via NVD·07:17 PM
DescriptionSeverityWeaknessAffected Software

Parent advisories

This vulnerability appears in the following advisories.

Frequently Asked Questions

1

Who can exploit this issue?

An unauthenticated attacker who has network access to the management network can exploit the ASMI web interface. Hosted partitions are not affected.

2

Is authentication or user interaction required?

No. The affected ASMI web interface can be targeted without authentication or user interaction, provided the attacker can reach it on the management network.

3

What is the operational impact of exploitation?

Exploitation can crash the ASMI web server, potentially cause memory corruption, and generate an error log. Although ASMI restarts automatically, repeated attacks can sustain loss of access to the ASMI management interface.

4

Which firmware levels are affected?

Affected levels are FW1120.00; FW1110.00 through FW1110.30; FW1060.00 through FW1060.80; and FW950.00 through FW950.H2.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203