CVE-2026-17429: Power System Incorrect Authorization

Published Aug 15, 2026
·
Updated

IBM Power Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 - OP940.81 (Power HMC) is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can write arbitrary data to hardware control registers, allowing full control over the host system and all hosted partitions, resulting in a confidentiality, integrity, and availability impact.

Other sources

Power Systems Firmware is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can write arbitrary data to hardware control registers, allowing full control over the host system and all hosted partitions, resulting in a confidentiality, integrity, and availability impact.

IBM

Affected Software

7 affected components
IBM Power Firmware>=FW1110.00<=FW1110.30, >=FW1060.00<=FW1060.80, >=FW950.00<=FW950.H2, >=OP940.00<=OP940.a1, >=OP940.00<=OP940.81
IBM Power HMC>=OP940.00<=OP940.81
IBM Power Firmware<=FW1120.00
IBM Power Firmware<=FW1110.00 - FW1110.30
IBM Power Firmware<=FW1060.00 - FW1060.80
IBM Power Firmware<=FW950.00 - FW950.H2
IBM Power Firmware<=OP940.00 - OP940.a1 (Power9)OP940.00 - OP940.81 (Power HMC)

Remediation

Recommended actions to resolve this vulnerability, in priority order.

  1. Upgrade

    Upgrade IBM Power Hardware Management Console (7063-CR2) to a version that resolves this vulnerability.

    Fixed in FW1060.81(1060_184)Patch FW1060.81(1060_184)
  2. Upgrade

    Upgrade IBM Power System AC922 (8335-GTH, 8335-GTX) to a version that resolves this vulnerability.

    Fixed in FW1110.31(1110_134)Patch FW1110.31(1110_134)
  3. Upgrade

    Upgrade IBM Power System E1050 (9043-MRX) to a version that resolves this vulnerability.

    Fixed in FW1110.31(1110_155)Patch FW1110.31(1110_155)
  4. Upgrade

    Upgrade IBM Power System E1080 (9080-HEX) to a version that resolves this vulnerability.

    Fixed in FW1120.01(1120_190)Patch FW1120.01(1120_190)
  5. Upgrade

    Upgrade IBM Power System E1150 (9043-MRU) to a version that resolves this vulnerability.

    Fixed in FW1120.01(1120_190)Patch FW1120.01(1120_190)
  6. Upgrade

    Upgrade IBM Power System E1180 (9080-HEU) to a version that resolves this vulnerability.

    Fixed in FW1120.01(1120_190)Patch FW1120.01(1120_190)
  7. Upgrade

    Upgrade IBM Power System E950 (9040-MR9) to a version that resolves this vulnerability.

    Fixed in FW950.H3(950_230)Patch FW950.H3(950_230)
  8. Upgrade

    Upgrade IBM Power System E980 (9080-M9S) to a version that resolves this vulnerability.

    Fixed in OP940.82Patch OP940.82
  9. Upgrade

    Upgrade IBM Power System H922 (9223-22S) to a version that resolves this vulnerability.

    Fixed in OP940.a2Patch OP940.a2
  10. Upgrade

    Upgrade IBM Power System H924 (9223-42S) to a version that resolves this vulnerability.

    Fixed in FW1060.81(1060_191)Patch FW1060.81(1060_191)
  11. Upgrade

    Upgrade IBM Power System L1022 (9786-22H) to a version that resolves this vulnerability.

    Fixed in FW1060.81(1060_191)Patch FW1060.81(1060_191)
  12. Upgrade

    Upgrade IBM Power System L1024 (9786-42H) to a version that resolves this vulnerability.

    Fixed in FW1060.81(1060_191)Patch FW1060.81(1060_191)
  13. Upgrade

    Upgrade IBM Power System L1122 (9856-22H) to a version that resolves this vulnerability.

    Fixed in FW1060.81(1060_191)Patch FW1060.81(1060_191)
  14. Upgrade

    Upgrade IBM Power System L1124 (9856-42H) to a version that resolves this vulnerability.

    Fixed in FW1060.81(1060_191)Patch FW1060.81(1060_191)
  15. Upgrade

    Upgrade IBM Power System S1012 (9028-21B) to a version that resolves this vulnerability.

    Fixed in FW1060.81(1060_191)Patch FW1060.81(1060_191)
  16. Upgrade

    Upgrade IBM Power System S1014 (9105-41B) to a version that resolves this vulnerability.

    Fixed in FW1060.81(1060_191)Patch FW1060.81(1060_191)
  17. Upgrade

    Upgrade IBM Power System S1022 (9105-22A) to a version that resolves this vulnerability.

    Fixed in FW1060.81(1060_191)Patch FW1060.81(1060_191)
  18. Upgrade

    Upgrade IBM Power System S1022s (9105-22B) to a version that resolves this vulnerability.

    Fixed in FW1060.81(1060_191)Patch FW1060.81(1060_191)
  19. Upgrade

    Upgrade IBM Power System S1024 (9105-42A) to a version that resolves this vulnerability.

    Fixed in FW1060.81(1060_191)Patch FW1060.81(1060_191)
  20. Upgrade

    Upgrade IBM Power System S1112 (9242-21B, 9242-21T) to a version that resolves this vulnerability.

    Fixed in FW1060.81(1060_191)Patch FW1060.81(1060_191)
  21. Upgrade

    Upgrade IBM Power System S1114 (9824-41B) to a version that resolves this vulnerability.

    Fixed in FW1060.81(1060_191)Patch FW1060.81(1060_191)
  22. Upgrade

    Upgrade IBM Power System S1122 (9824-22A) to a version that resolves this vulnerability.

    Fixed in FW1060.81(1060_191)Patch FW1060.81(1060_191)
  23. Upgrade

    Upgrade IBM Power System S1122s (9824-22B) to a version that resolves this vulnerability.

    Fixed in FW1060.81(1060_191)Patch FW1060.81(1060_191)
  24. Upgrade

    Upgrade IBM Power System S1124 (9824-42A) to a version that resolves this vulnerability.

    Fixed in FW1060.81(1060_191)Patch FW1060.81(1060_191)
  25. Upgrade

    Upgrade IBM Power System S914 (9009-41G) to a version that resolves this vulnerability.

    Fixed in FW1060.81(1060_191)Patch FW1060.81(1060_191)
  26. Upgrade

    Upgrade IBM Power System S922 (9009-22G) to a version that resolves this vulnerability.

    Fixed in FW1060.81(1060_191)Patch FW1060.81(1060_191)
  27. Upgrade

    Upgrade IBM Power System S924 (9009-42G) to a version that resolves this vulnerability.

    Fixed in FW1060.81(1060_191)Patch FW1060.81(1060_191)

Event History

Aug 15, 2026
CVE Published
via IBM·12:00 AM
Data Sourced
via IBM·12:00 AM
DescriptionAffected Software
Aug 19, 2026
CVE Published
via MITRE·06:40 PM
Data Sourced
via MITRE·06:40 PM
RemedyDescriptionSeverityWeakness

Parent advisories

This vulnerability appears in the following advisories.

Frequently Asked Questions

1

What level of access is required to exploit this issue?

An attacker needs service account or root access to the BMC/FSP. The issue is locally exploitable and does not require user interaction.

2

What systems are exposed if the BMC/FSP is compromised?

A successful attacker can gain full control of the host system and all hosted partitions. This can affect confidentiality, integrity, and availability across the managed system.

3

Which firmware releases are identified as affected?

Affected releases include FW1120.00; FW1110.00 through FW1110.30; FW1060.00 through FW1060.80; FW950.00 through FW950.H2; OP940.00 through OP940.a1 for Power9; and OP940.00 through OP940.81 for Power HMC.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203