CVE-2026-33780: Junos OS and Junos OS Evolved: In an EVPN-MPLS scenario churn of ESI routes causes a memory leak in l2ald

Published Apr 9, 2026
·
Updated

A Missing Release of Memory after Effective Lifetime vulnerability in the Layer 2 Address Learning Daemon (l2ald) of Juniper Networks Junos OS and Junos OS Evolved allows an adjacent, unauthenticated attacker to cause a memory leak ultimately leading to a Denial of Service (DoS).

In an EVPN-MPLS scenario, routes learned from remote multi-homed Provider Edge (PE) devices are programmed as ESI routes. Due to a logic issue in the l2ald memory management, memory allocated for these routes is not released when there is churn for these routes. As a result, memory leaks in the l2ald process which will ultimately lead to a crash and restart of l2ald.

Use the following command to monitor the memory consumption by l2ald:

user@device> show system process extensive | match "PID|l2ald"

This issue affects:

Junos OS:

all versions before 22.4R3-S5, 23.2 versions before 23.2R2-S3, 23.4 versions before 23.4R2-S4, 24.2 versions before 24.2R2;

Junos OS Evolved:

all versions before 22.4R3-S5-EVO, 23.2 versions before 23.2R2-S3-EVO, 23.4 versions before 23.4R2-S4-EVO, 24.2 versions before 24.2R2-EVO.

Affected Software

65 affected components
Juniper Networks Junos OS<22.4R3-S5, <23.2R2-S3, <23.4R2-S4, <24.2R2
Juniper Networks Junos OS Evolved<22.4R3-S5-EVO, <23.2R2-S3-EVO, <23.4R2-S4-EVO, <24.2R2-EVO
Juniper Junos<22.4
Juniper Junos=22.4
Juniper Junos=22.4-r1
Juniper Junos=22.4-r1-s1
Juniper Junos=22.4-r1-s2
Juniper Junos=22.4-r2
Juniper Junos=22.4-r2-s1
Juniper Junos=22.4-r2-s2
Juniper Junos=22.4-r3
Juniper Junos=22.4-r3-s1
Juniper Junos=22.4-r3-s2
Juniper Junos=22.4-r3-s3
Juniper Junos=22.4-r3-s4
Juniper Junos=23.2
Juniper Junos=23.2-r1
Juniper Junos=23.2-r1-s1
Juniper Junos=23.2-r1-s2
Juniper Junos=23.2-r2
Juniper Junos=23.2-r2-s1
Juniper Junos=23.2-r2-s2
Juniper Junos=23.4
Juniper Junos=23.4-r1
Juniper Junos=23.4-r1-s1
Juniper Junos=23.4-r1-s2
Juniper Junos=23.4-r2
Juniper Junos=23.4-r2-s1
Juniper Junos=23.4-r2-s2
Juniper Junos=23.4-r2-s3
Juniper Junos=24.2
Juniper Junos=24.2-r1
Juniper Junos=24.2-r1-s1
Juniper Junos=24.2-r1-s2
Juniper Junos OS Evolved<22.4
Juniper Junos OS Evolved=22.4
Juniper Junos OS Evolved=22.4-r1
Juniper Junos OS Evolved=22.4-r1-s1
Juniper Junos OS Evolved=22.4-r1-s2
Juniper Junos OS Evolved=22.4-r2
Juniper Junos OS Evolved=22.4-r2-s1
Juniper Junos OS Evolved=22.4-r2-s2
Juniper Junos OS Evolved=22.4-r3
Juniper Junos OS Evolved=22.4-r3-s1
Juniper Junos OS Evolved=22.4-r3-s2
Juniper Junos OS Evolved=22.4-r3-s3
Juniper Junos OS Evolved=22.4-r3-s4
Juniper Junos OS Evolved=23.2
Juniper Junos OS Evolved=23.2-r1
Juniper Junos OS Evolved=23.2-r1-s1
Juniper Junos OS Evolved=23.2-r1-s2
Juniper Junos OS Evolved=23.2-r2
Juniper Junos OS Evolved=23.2-r2-s1
Juniper Junos OS Evolved=23.2-r2-s2
Juniper Junos OS Evolved=23.4
Juniper Junos OS Evolved=23.4-r1
Juniper Junos OS Evolved=23.4-r1-s1
Juniper Junos OS Evolved=23.4-r1-s2
Juniper Junos OS Evolved=23.4-r2
Juniper Junos OS Evolved=23.4-r2-s1
Juniper Junos OS Evolved=23.4-r2-s2
Juniper Junos OS Evolved=23.4-r2-s3
Juniper Junos OS Evolved=24.2
Juniper Junos OS Evolved=24.2-r1
Juniper Junos OS Evolved=24.2-r1-s2

Remediation

Information

The following software releases have been updated to resolve this specific issue: Junos OS Evolved: 22.4R3-S5-EVO, 23.2R2-S3-EVO, 23.4R2-S4-EVO, 24.2R2-EVO, 24.4R1-EVO, and all subsequent releases; Junos OS: 22.4R3-S5, 23.2R2-S3, 23.4R2-S4, 24.2R2, 24.4R1, and all subsequent releases.

Event History

Apr 9, 2026
CVE Published
via MITRE·09:29 PM
Data Sourced
via MITRE·09:29 PM
RemedyDescriptionSeverityWeakness
Data Sourced
via NVD·10:16 PM
DescriptionSeverityWeaknessAffected Software
Free Weekly Intel

Don't miss critical vulnerabilities

Join thousands of security professionals who receive our weekly digest of trending CVEs, zero-days, and exploited vulnerabilities.

No spam. Unsubscribe anytime.

Frequently Asked Questions

1

What is the severity of CVE-2026-33780?

CVE-2026-33780 is considered a high severity vulnerability due to its potential to cause memory leaks in network devices.

2

What software versions are affected by CVE-2026-33780?

CVE-2026-33780 affects Juniper Networks Junos OS versions up to 22.4R3-S5 and Junos OS Evolved versions up to 22.4R3-S5-EVO.

3

How do I fix CVE-2026-33780?

Fixing CVE-2026-33780 involves upgrading to the latest patched versions of Junos OS or Junos OS Evolved provided by Juniper Networks.

4

What impact does CVE-2026-33780 have on network operations?

CVE-2026-33780 can lead to service degradation and interruptions due to memory exhaustion in affected networking devices.

5

Is authentication necessary to exploit CVE-2026-33780?

No, CVE-2026-33780 can be exploited by an adjacent, unauthenticated attacker, making it particularly concerning for network security.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203