CVE-2026-3557: (Pwn2Own) Philips Hue Bridge hap_pair_verify_handler Sub-TLV Parsing Heap-based Buffer Overflow Remote Code Execution Vulnerability

Published Mar 13, 2026
·
Updated

Philips Hue Bridge happairverifyhandler Sub-TLV Parsing Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.

The specific flaw exists within the happairverifyhandler function of the hkhap service, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-28337.

Affected Software

4 affected components
Philips Hue Bridge
Philips Hue Bridge
All of the following
Philips Hue Bridge V2 Firmware<1975170000
Philips Hue Bridge V2

Event History

Mar 13, 2026
CVE Published
via MITRE·08:36 PM
Data Sourced
via MITRE·08:36 PM
DescriptionSeverityWeakness
Advisory Published
via ZDI·08:54 PM
Data Sourced
via ZDI·08:54 PM
DescriptionSeverityAffected Software
Mar 16, 2026
Data Sourced
via NVD·02:19 PM
DescriptionSeverityWeaknessAffected Software
Free Weekly Intel

Don't miss critical vulnerabilities

Join thousands of security professionals who receive our weekly digest of trending CVEs, zero-days, and exploited vulnerabilities.

No spam. Unsubscribe anytime.

Frequently Asked Questions

1

What is the severity of CVE-2026-3557?

CVE-2026-3557 is classified as a critical vulnerability due to its potential for remote code execution.

2

How do I fix CVE-2026-3557?

To mitigate CVE-2026-3557, ensure your Philips Hue Bridge firmware is updated to the latest version provided by Philips.

3

Who is affected by CVE-2026-3557?

CVE-2026-3557 affects users of the Philips Hue Bridge that are running unpatched versions.

4

What type of attack can exploit CVE-2026-3557?

CVE-2026-3557 can be exploited through a heap-based buffer overflow, allowing attackers to execute code remotely.

5

Is CVE-2026-3557 a local or remote vulnerability?

CVE-2026-3557 is a remote vulnerability, requiring network adjacency for successful exploitation.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203