CVE-2026-53364: Bluetooth: hci_conn: Fix memory leak in hci_le_big_terminate()

Published Jul 13, 2026
·
Updated

In the Linux kernel, the following vulnerability has been resolved:

Bluetooth: hciconn: Fix memory leak in hcilebigterminate()

hcilebigterminate() allocates isolistdata via kzallocobj but returns 0 without freeing it when neither pasyncterm nor bigsyncterm flags are set after evaluating the PA and BIG sync connection state.

This early-return path was introduced when hcilebigterminate() was refactored to take struct hciconn instead of raw u8 parameters, adding PA/BIG flag evaluation logic. The existing kfree() on hcicmdsyncqueue failure does not cover this path.

Affected Software

8 affected components
Linux Linux kernel
Linux Linux kernel>=6.16.4<6.18.35
Linux Linux kernel>=6.19<7.0.12
Linux Linux kernel=7.1-rc1
Linux Linux kernel=7.1-rc2
Linux Linux kernel=7.1-rc3
Linux Linux kernel=7.1-rc4
Linux Linux kernel=7.1-rc5

Remediation

Recommended actions to resolve this vulnerability, in priority order.

  1. Compensating control

    Apply the Linux kernel security fix for the Bluetooth vulnerability described as a resolution to “Bluetooth: hci_conn: Fix memory leak in hci_le_big_terminate()” (PA/BIG flag evaluation logic / missing free on early-return path).

Event History

Jul 13, 2026
CVE Published
via MITRE·05:33 PM
Data Sourced
via MITRE·05:33 PM
Description
Data Sourced
via NVD·06:16 PM
RemedyDescriptionSeverityWeaknessAffected Software

Frequently Asked Questions

1

What is the severity of CVE-2026-53364?

The severity of CVE-2026-53364 is rated as 5.

2

How do I fix CVE-2026-53364?

To fix CVE-2026-53364, update the Linux kernel to the latest version where the memory leak is addressed.

3

What systems are affected by CVE-2026-53364?

CVE-2026-53364 affects the Linux kernel, particularly systems utilizing Bluetooth functionality.

4

What are the potential impacts of CVE-2026-53364?

The potential impact of CVE-2026-53364 includes memory leaks that can lead to performance degradation over time.

5

Is CVE-2026-53364 exploitable remotely?

CVE-2026-53364 is primarily related to local memory management and does not indicate remote exploitation capabilities.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.