CVE-2026-70606: Electron: ProtocolResponse.url reuses the default session cache instead of the registering session

Published Aug 5, 2026
·
Updated

Impact When a custom protocol handler returned a ProtocolResponse with a url and no session, Electron made the upstream request through defaultSession instead of the session that handled the protocol. A cached response could then be reused across otherwise isolated session partitions.

Apps that use ProtocolResponse.url, omit ProtocolResponse.session, and rely on separate sessions to isolate content are affected. Apps that set an explicit session, or that do not isolate content across sessions, are not affected.

Workarounds Set ProtocolResponse.session explicitly so the request uses the intended session's cache.

Fixed Versions 43.0.0 42.5.1 41.9.1 40.10.6

For more information If you have any questions or comments about this advisory, email Electron at security@electronjs.org

Other sources

Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. Prior to 40.10.6, 41.9.1, 42.5.1, and 43.0.0, when a custom protocol handler returned a ProtocolResponse with a url and no session, Electron made the upstream request through defaultSession instead of the session that handled the protocol. A cached response could then be reused across otherwise isolated session partitions. Apps that use ProtocolResponse.url, omit ProtocolResponse.session, and rely on separate sessions to isolate content are affected. This issue is fixed in versions 40.10.6, 41.9.1, 42.5.1, and 43.0.0.

— MITRE

Affected Software

12 affected componentsFixes available
npm/electron>=40.0.0-alpha.1<40.10.6
40.10.6
npm/electron>=41.0.0-alpha.1<41.9.1
41.9.1
npm/electron>=42.0.0-alpha.1<42.5.1
42.5.1
npm/electron>=43.0.0-alpha.1<43.0.0
43.0.0
electronjs Electron Node.js<40.10.6
electronjs Electron Node.js>=41.0.0<=41.9.1
electronjs Electron Node.js>=42.0.0<=42.5.1
electronjs Electron Node.js=43.0.0-alpha1
electronjs Electron Node.js=43.0.0-alpha2
electronjs Electron Node.js=43.0.0-alpha3
electronjs Electron Node.js=43.0.0-alpha4
electronjs Electron Node.js=43.0.0-alpha5

Remediation

Recommended actions to resolve this vulnerability, in priority order.

  1. Upgrade

    Upgrade npm/electron to a version that resolves this vulnerability.

    Fixed in 40.10.6
  2. Upgrade

    Upgrade npm/electron to a version that resolves this vulnerability.

    Fixed in 41.9.1
  3. Upgrade

    Upgrade npm/electron to a version that resolves this vulnerability.

    Fixed in 42.5.1
  4. Upgrade

    Upgrade npm/electron to a version that resolves this vulnerability.

    Fixed in 43.0.0
  5. Upgrade

    Upgrade electron/electron to a version that resolves this vulnerability.

    Fixed in 40.10.6
  6. Upgrade

    Upgrade electron/electron to a version that resolves this vulnerability.

    Fixed in 41.9.1
  7. Upgrade

    Upgrade electron/electron to a version that resolves this vulnerability.

    Fixed in 42.5.1
  8. Upgrade

    Upgrade electron/electron to a version that resolves this vulnerability.

    Fixed in 43.0.0
  9. Configuration

    If a custom protocol handler returns a ProtocolResponse with a ProtocolResponse.url and no ProtocolResponse.session, set ProtocolResponse.session explicitly so the upstream request uses the intended session cache instead of defaultSession.

    Electron custom protocol handler (ProtocolResponse) ProtocolResponse.session = Set explicitly (do not omit when returning ProtocolResponse.url)

Event History

Aug 5, 2026
CVE Published
via MITRE·04:07 PM
Data Sourced
via MITRE·04:07 PM
DescriptionSeverityWeakness
Advisory Published
via GitHub·04:07 PM
Data Sourced
via GitHub·04:07 PM
DescriptionSeverityWeaknessAffected Software
Data Sourced
via NVD·04:17 PM
DescriptionSeverityWeaknessAffected Software

Frequently Asked Questions

1

What is the severity of CVE-2026-70606?

The severity of CVE-2026-70606 is medium with a score of 5.9.

2

How do I fix CVE-2026-70606?

To address CVE-2026-70606, ensure you are using the latest version of Electron that contains the fix for this vulnerability.

3

What impact does CVE-2026-70606 have on my application?

CVE-2026-70606 allows a cached response to be reused across isolated session partitions, potentially exposing sensitive data.

4

Which software is affected by CVE-2026-70606?

CVE-2026-70606 affects the Electron framework, specifically versions prior to the fix.

5

When was CVE-2026-70606 published?

CVE-2026-70606 was published on August 5, 2026.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203