CVE-2026-80149: Lantronix Autonomous Out-of-Band Devices WebSSH SSRF via rooturl Parameter

Published Sep 22, 2026
·
Updated

Lantronix SLC8000 before firmware v9.7.0.3, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish SSH connections to attacker-controlled endpoints. The custom shellinaboxd uses the rooturl parameter from the web connection to determine its own IP address; by modifying this parameter an attacker redirects the SSH terminal connection to an arbitrary host or IP. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible.

Affected Software

4 affected components
Lantronix SLC8000<9.7.0.3
Lantronix EMG8500<9.7.0.1
Lantronix EMG7500<9.7.0.1
Lantronix SLB882

Remediation

Recommended actions to resolve this vulnerability, in priority order.

  1. Upgrade

    Upgrade Lantronix SLC8000 to a version that resolves this vulnerability.

    Fixed in 9.7.0.3
  2. Upgrade

    Upgrade Lantronix EMG8500/EMG7500 to a version that resolves this vulnerability.

    Fixed in 9.7.0.1

Event History

Sep 22, 2026
CVE Published
via MITRE·03:20 PM
Data Sourced
via MITRE·03:20 PM
DescriptionSeverityWeakness
Data Sourced
via NVD·04:18 PM
DescriptionSeverityWeakness

Frequently Asked Questions

1

Which deployments are exposed?

Devices running the WebSSH/WebTelnet listener are exposed: SLC8000 firmware earlier than 9.7.0.3, EMG8500 and EMG7500 firmware earlier than 9.7.0.1, and SLB882 devices running any firmware version.

2

Does exploitation require authentication or user interaction?

No. The issue is reachable over the network and can be exploited by an unauthenticated attacker without user interaction.

3

What can an attacker do with this vulnerability?

An attacker can alter the rooturl parameter so the device initiates an SSH connection to an arbitrary attacker-selected host or IP. This can be used to enumerate or communicate with internal endpoints that are otherwise inaccessible.

4

What should be patched first?

Upgrade SLC8000 devices to firmware 9.7.0.3 or later and EMG8500/EMG7500 devices to firmware 9.7.0.1 or later. The provided information states that all SLB882 firmware versions are affected and does not identify a fixed version.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.