CVE-2026-80155: Lantronix Autonomous Out-of-Band Devices Unauthenticated Authentication Bypass via snprintf Path Truncation

Published Sep 22, 2026
·
Updated

Lantronix SLC8000 before firmware v9.7.0.5, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain an authentication bypass vulnerability in the web management portal upload endpoint that allows unauthenticated attackers to read sensitive configuration files and upload files to arbitrary filesystem locations, leading to remote code execution. The web configuration server constructs the session cookie file path using snprintf with a fixed-size buffer; by supplying a cookie value of a specific length an attacker causes the path to truncate at the required delimiter and leverages path traversal to redirect authentication validation to an arbitrary on-disk file such as the local user database, bypassing all session checks. Attackers can use this vulnerability to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-connected devices.

Affected Software

6 affected components
Lantronix SLC8000<9.7.0.5
Lantronix EMG8500<9.7.0.1
Lantronix EMG7500<9.7.0.1
Lantronix SLB882
Lantronix SLCx-03
Lantronix SLCx-02

Remediation

Recommended actions to resolve this vulnerability, in priority order.

  1. Upgrade

    Upgrade Lantronix SLC8000 to a version that resolves this vulnerability.

    Fixed in v9.7.0.5
  2. Upgrade

    Upgrade Lantronix EMG8500/EMG7500 to a version that resolves this vulnerability.

    Fixed in v9.7.0.1

Event History

Sep 22, 2026
CVE Published
via MITRE·03:22 PM
Data Sourced
via MITRE·03:22 PM
DescriptionSeverityWeakness
Data Sourced
via NVD·04:18 PM
DescriptionSeverityWeakness

Frequently Asked Questions

1

Which devices and firmware releases are affected?

Affected devices are SLC8000 running firmware before v9.7.0.5 and EMG8500 or EMG7500 running firmware before v9.7.0.1. All firmware versions of SLB882, SLCx-03, and SLCx-02 are affected.

2

Does exploitation require credentials or user interaction?

No. An unauthenticated remote attacker can target the web management portal upload endpoint, and no user interaction is required.

3

What access can an attacker gain after exploiting the issue?

An attacker can read sensitive configuration files and upload files to arbitrary filesystem locations, which can lead to remote code execution. This can result in complete loss of confidentiality, integrity, and availability on the device and may affect downstream serial-connected devices.

4

What should be prioritized for remediation?

Upgrade SLC8000 devices to firmware v9.7.0.5 or later, and EMG8500 and EMG7500 devices to firmware v9.7.0.1 or later. SLB882, SLCx-03, and SLCx-02 devices are affected across all firmware versions, so they require compensating measures where applicable.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.