CVE-2026-81818: Flowintel Organization Administrator Can Reset Full Administrator Password and Escalate Privileges

Published Aug 27, 2026
·
Updated

Affected versions of Flowintel contain an authorization flaw in the administrative user-edit API.

The existing authorization check correctly prevented an organization administrator from editing users in another organization, but it did not prevent them from editing a full administrator within their own organization. As a result, an org admin could modify that full administrator account, including changing its password. The upstream commit explicitly describes the issue as:

“Org admin can change the password of a full admin in the same organization.”

The fix adds a higher-privilege boundary check:

if usertoedit.isadmin(): return ... 403

so organization administrators can no longer modify full administrator accounts.

Version impacted >=3.3.0

Affected Software

1 affected component
Flowintel>=undefined

Event History

Aug 27, 2026
CVE Published
via MITRE·01:14 PM
Data Sourced
via MITRE·01:14 PM
DescriptionWeakness
Data Sourced
via NVD·05:21 PM
DescriptionSeverityWeakness

Frequently Asked Questions

1

Who can exploit this issue?

A Flowintel organization administrator can exploit it against a full administrator account in the same organization. The flaw does not permit the organization administrator to edit users in another organization.

2

What level of access can exploitation provide?

The organization administrator can change the full administrator's password through the administrative user-edit API. This can allow the organization administrator to take over that full administrator account and escalate privileges.

3

Are affected deployments vulnerable by default?

Affected Flowintel versions are vulnerable when an organization administrator and a full administrator belong to the same organization, because the vulnerable authorization check allowed the organization administrator to edit that full administrator account.

4

What mitigation is indicated by the fix?

Prevent organization administrators from modifying accounts identified as full administrators in the administrative user-edit API. The upstream fix returns a 403 response when the user being edited is a full administrator.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203