CVE-2026-85068: NUT blazer_usb ippon_command stack info-leak via unzeroed char tmp[64] in OUT-direction usb_control_msg

Published Nov 5, 2026
·
Updated

Network UPS Tools is a collection of programs which provide a common interface for monitoring and administering UPS, PDU and SCD hardware. From 2.4.2 through 2.8.5, ipponcommand in drivers/blazerusb.c partially initializes char tmp[64] with a short Megatec status query and then passes a fixed eight-byte chunk to usbcontrolmsg. A malicious firmware-controlled USB device presenting the Mustek Powermust VID 0x06da and Mustek Powermust PID 0x0003 matches blazerusbid, selects ipponsubdriver, and can receive the uninitialized trailing stack bytes during normal polling. The disclosure is bounded and read-only, requires physical or supply-chain access to the USB bus, and has no established integrity or availability impact. This issue is scheduled to be fixed in version 2.8.6.

Remediation

Recommended actions to resolve this vulnerability, in priority order.

  1. Upgrade

    Upgrade Network UPS Tools (NUT) to a version that resolves this vulnerability.

    Fixed in 2.8.6

Event History

Nov 5, 2026
CVE Published
via MITRE·10:57 PM
Data Sourced
via MITRE·10:57 PM
DescriptionSeverityWeakness
Data Sourced
via NVD·11:17 PM
DescriptionSeverityWeakness

Frequently Asked Questions

1

Which deployments are realistically exposed?

Deployments using NUT versions 2.4.2 through 2.8.5 with a USB device that matches the Mustek Powermust VID 0x06da and PID 0x0003 are exposed when the device is handled by the blazer_usb driver and selects the ippon_subdriver.

2

What does an attacker need to exploit this issue?

An attacker needs physical or supply-chain access to the USB bus and control of firmware on a malicious USB device presenting the affected Mustek Powermust vendor and product identifiers. The leak occurs during normal polling.

3

What information can be disclosed?

The device can receive uninitialized trailing stack bytes from a fixed eight-byte USB control transfer after the short Megatec status query is placed in tmp[64]. The disclosure is bounded and read-only; no integrity or availability impact is established.

4

What should be done if an immediate upgrade is not possible?

Restrict physical and supply-chain access to the USB bus and avoid connecting untrusted USB devices that can present the affected Mustek Powermust identifiers. The scheduled fixed version is 2.8.6.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.