ZDI-24-017: Inductive Automation Ignition ResponseParser Notification Deserialization of Untrusted Data Remote Code Execution Vulnerability

Published Jan 5, 2024
·
Updated

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. User interaction is required to exploit this vulnerability in that the target must connect to a malicious server. The specific flaw exists within the ResponseParser method. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of the current user.

Other sources

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. User interaction is required to exploit this vulnerability in that the target must connect to a malicious server. The ZDI has assigned a CVSS rating of 8.8. The following CVEs are assigned: CVE-2023-50222.

ZDI

Affected Software

1 affected component
Inductive Automation Ignition

Event History

Jan 5, 2024
Advisory Published
via ZDI·06:00 AM
Data Sourced
via ZDI·06:00 AM
Description
Mar 28, 2025
Advisory Published
via ZDI·02:08 AM

Frequently Asked Questions

1

What is the severity of ZDI-24-017?

ZDI-24-017 is considered a critical vulnerability due to its potential for remote code execution.

2

How do I fix ZDI-24-017?

To fix ZDI-24-017, ensure you update your Inductive Automation Ignition software to the latest version provided by the vendor.

3

What are the risks associated with ZDI-24-017?

The primary risk of ZDI-24-017 is the possibility of remote code execution by attackers, leading to potential unauthorized actions on the server.

4

Is user interaction required to exploit ZDI-24-017?

Yes, user interaction is required for ZDI-24-017 as the target must connect to a malicious server.

5

What software is affected by ZDI-24-017?

ZDI-24-017 affects the Inductive Automation Ignition software.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.