ZDI-24-1050: (0Day) (Pwn2Own) ChargePoint Home Flex SrvrToSmSetAutoChnlListMsg Stack-based Buffer Overflow Remote Code Execution Vulnerability

Published Aug 1, 2024
·
Updated

This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of ChargePoint Home Flex charging stations. Authentication is not required to exploit this vulnerability. The specific flaw exists within the SrvrToSmSetAutoChnlListMsg function. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of root.

Other sources

This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of ChargePoint Home Flex charging stations. Authentication is not required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 8.8. The following CVEs are assigned: CVE-2024-23968.

ZDI

Affected Software

2 affected components
ChargePoint Home Flex
ChargePoint Home Flex

Event History

Aug 1, 2024
Advisory Published
via ZDI·05:00 AM
Data Sourced
via ZDI·05:00 AM
Description
Feb 21, 2025
Advisory Published
via ZDI·05:04 PM
Free Weekly Intel

Don't miss critical vulnerabilities

Join thousands of security professionals who receive our weekly digest of trending CVEs, zero-days, and exploited vulnerabilities.

No spam. Unsubscribe anytime.

Frequently Asked Questions

1

What is the severity of ZDI-24-1050?

ZDI-24-1050 is considered a critical vulnerability due to its potential for arbitrary code execution without authentication.

2

How do I fix ZDI-24-1050?

To fix ZDI-24-1050, ensure you update the ChargePoint Home Flex firmware to the latest version provided by ChargePoint.

3

Who is affected by ZDI-24-1050?

ZDI-24-1050 affects installations of ChargePoint Home Flex charging stations.

4

What type of vulnerability is ZDI-24-1050?

ZDI-24-1050 is a code execution vulnerability that allows attackers to execute arbitrary code on affected systems.

5

Is authentication required to exploit ZDI-24-1050?

No, authentication is not required to exploit the ZDI-24-1050 vulnerability.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.