ZDI-24-1347: Tungsten Automation Power PDF TIF File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability

Published Oct 11, 2024
·
Updated

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Tungsten Automation Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of TIF files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.

Other sources

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Tungsten Automation Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2024-9745.

ZDI

Affected Software

1 affected component
Tungsten Automation Power PDF

Event History

Oct 11, 2024
Advisory Published
via ZDI·05:00 AM
Data Sourced
via ZDI·05:00 AM
Description
Feb 25, 2025
Advisory Published
via ZDI·05:57 PM

Frequently Asked Questions

1

What is the severity of ZDI-24-1347?

The vulnerability ZDI-24-1347 is considered critical due to its potential for remote code execution.

2

How do I fix ZDI-24-1347?

To mitigate ZDI-24-1347, users should update Tungsten Automation Power PDF to the latest version available.

3

What types of attacks can ZDI-24-1347 facilitate?

ZDI-24-1347 can enable remote attackers to execute arbitrary code if the user visits a malicious page or opens a malicious file.

4

Is user interaction required to exploit ZDI-24-1347?

Yes, user interaction is necessary for exploiting ZDI-24-1347 as the target must visit a malicious page or open a vulnerable file.

5

Which software is affected by ZDI-24-1347?

The vulnerability ZDI-24-1347 affects Tungsten Automation Power PDF.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.