ZDI-24-1679: Tungsten Automation Power PDF JP2 File Parsing Out-Of-Bounds Read Remote Code Execution Vulnerability

Published Dec 11, 2024
·
Updated

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Tungsten Automation Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of JP2 files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated object. An attacker can leverage this vulnerability to execute code in the context of the current process.

Other sources

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Tungsten Automation Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2024-12549.

ZDI

Affected Software

2 affected components
Tungsten Automation Power PDF
Tungsten Automation Power PDF

Event History

Dec 11, 2024
Advisory Published
via ZDI·06:00 AM
Data Sourced
via ZDI·06:00 AM
Description
Feb 26, 2025
Advisory Published
via ZDI·12:45 AM
Free Weekly Intel

Don't miss critical vulnerabilities

Join thousands of security professionals who receive our weekly digest of trending CVEs, zero-days, and exploited vulnerabilities.

No spam. Unsubscribe anytime.

Frequently Asked Questions

1

What is the severity of ZDI-24-1679?

The severity of ZDI-24-1679 is high due to its ability to allow remote code execution.

2

How do I fix ZDI-24-1679?

To fix ZDI-24-1679, update Tungsten Automation Power PDF to the latest version provided by the vendor.

3

What does ZDI-24-1679 affect?

ZDI-24-1679 affects installations of Tungsten Automation Power PDF.

4

What type of attack is involved in ZDI-24-1679?

ZDI-24-1679 involves a remote code execution attack requiring user interaction.

5

What is the exploit vector for ZDI-24-1679?

The exploit vector for ZDI-24-1679 is through visiting a malicious page or opening a malicious file.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.