ZDI-24-1722: (0Day) Delta Electronics DRASimuCAD STP File Parsing Type Confusion Remote Code Execution Vulnerability

Published Dec 20, 2024
·
Updated

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics DRASimuCAD. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of STP files. The issue results from the lack of proper validation of user-supplied data, which can result in a type confusion condition. An attacker can leverage this vulnerability to execute code in the context of the current process.

Other sources

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics DRASimuCAD. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2024-12834.

ZDI

Affected Software

1 affected component
Delta Electronics DRASimuCAD

Event History

Dec 20, 2024
Advisory Published
via ZDI·06:00 AM
Data Sourced
via ZDI·06:00 AM
Description
Dec 30, 2024
Advisory Published
via ZDI·04:58 PM
Free Weekly Intel

Don't miss critical vulnerabilities

Join thousands of security professionals who receive our weekly digest of trending CVEs, zero-days, and exploited vulnerabilities.

No spam. Unsubscribe anytime.

Frequently Asked Questions

1

What is the severity of ZDI-24-1722?

The severity of ZDI-24-1722 is critical due to its ability to allow remote code execution.

2

How do I fix ZDI-24-1722?

To fix ZDI-24-1722, ensure that you apply the latest security updates and patches provided by Delta Electronics for DRASimuCAD.

3

Who are the affected users of ZDI-24-1722?

The affected users of ZDI-24-1722 are those using Delta Electronics DRASimuCAD software.

4

What type of attack is associated with ZDI-24-1722?

ZDI-24-1722 is associated with remote code execution attacks that require user interaction.

5

Is user interaction required to exploit ZDI-24-1722?

Yes, user interaction is required to exploit ZDI-24-1722, typically by visiting a malicious site or opening a malicious file.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.