ZDI-CAN-28276: ZDI-26-153: (Pwn2Own) Philips Hue Bridge Zigbee Stack Custom Command Handler Heap-based Buffer Overflow Remote Code Execution Vulnerability

Published Mar 6, 2026
·
Updated

This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. User interaction is required to exploit this vulnerability in that the user must initiate the device pairing process. The specific flaw exists within the handling of custom Zigbee ZCL frames in the Model Info download functionality. The issue results from the lack of proper validation of the size of data prior to copying it to a fixed-size heap buffer. An attacker can leverage this vulnerability to execute code in the context of the device.

Other sources

This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. User interaction is required to exploit this vulnerability in that the user must initiate the device pairing process. The ZDI has assigned a CVSS rating of 8.0. The following CVEs are assigned: CVE-2026-3555.

ZDI

Affected Software

2 affected components
Philips Hue Bridge
Philips Hue Bridge

Event History

Mar 6, 2026
Advisory Published
via ZDI·06:00 AM
Data Sourced
via ZDI·06:00 AM
Description
Mar 13, 2026
Advisory Published
via ZDI·08:54 PM
Data Sourced
via ZDI·08:54 PM
SeverityAffected Software
Free Weekly Intel

Don't miss critical vulnerabilities

Join thousands of security professionals who receive our weekly digest of trending CVEs, zero-days, and exploited vulnerabilities.

No spam. Unsubscribe anytime.

Frequently Asked Questions

1

What is the severity of ZDI-CAN-28276?

ZDI-CAN-28276 is considered a critical vulnerability due to its potential for remote code execution.

2

How do I fix ZDI-CAN-28276?

To mitigate ZDI-CAN-28276, ensure that your Philips Hue Bridge is updated to the latest firmware version provided by Philips.

3

What type of attack is ZDI-CAN-28276 associated with?

ZDI-CAN-28276 is associated with a heap-based buffer overflow that allows for remote code execution.

4

What are the implications of ZDI-CAN-28276?

The implications of ZDI-CAN-28276 include the potential for attackers to execute arbitrary code and take control of the affected Philips Hue Bridge.

5

Is user interaction required to exploit ZDI-CAN-28276?

Yes, user interaction is required to exploit ZDI-CAN-28276, which may complicate the attack vector.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.