A improper neutralization of script-related html tags in a web page (basic xss) vulnerability in Fortinet FortiADC 8.0.0, FortiADC 7.6.0 through 7.6.3, FortiADC 7.4 all versions, FortiADC 7.2 all versions may allow attacker to execute unauthorized code or commands via crafted URL.
An Out-of-bounds Write vulnerability [CWE-787] in FortiADC 8.0.0, 7.6.0 through 7.6.2, 7.4.0 through 7.4.7, 7.2 all versions, 7.1 all versions, 7.0 all versions, 6.2 all versions may allow an authenticated attacker to execute arbitrary code via specially crafted HTTP requests.
An exposure of sensitive information to an unauthorized actor vulnerability in Fortinet FortiADC 7.4.0, FortiADC 7.2 all versions, FortiADC 7.1 all versions, FortiADC 7.0 all versions, FortiADC 6.2 all versions may allow an admin with read-only permission to get the external resources password via the logs of the product
An exposure of sensitive information to an unauthorized actor vulnerability [CWE-200] in Fortinet FortiADC version 7.4.0, version 7.2.3 and below, version 7.1.4 and below, 7.0 all versions, 6.2 all versions may allow an authenticated attacker to obtain sensitive data via crafted HTTP or HTTPs requests.
An improper neutralization of special elements used in an OS Command ("OS Command Injection") vulnerability [CWE-78] in Fortinet FortiADC version 7.2.0 and before 7.1.1 allows a remote and authenticated attacker with low privilege to execute unauthorized code via specifically crafted HTTP parameters.
A improper neutralization of special elements used in an os command ('os command injection') vulnerability in Fortinet FortiADC 7.6.0 through 7.6.1, FortiADC 7.4.0 through 7.4.6, FortiADC 7.2.0 through 7.2.7, FortiADC 7.1.0 through 7.1.4, FortiADC 7.0 all versions, FortiADC 6.2 all versions, FortiADC 6.1 all versions, FortiADC 6.0 all versions, FortiADC 5.4 all versions, FortiADC 5.3 all versions, FortiADC 5.2 all versions, FortiADC 5.1 all versions, FortiADC 5.0 all versions, FortiADC 4.8 all versions, FortiADC 4.7 all versions, FortiADC 4.6 all versions, FortiADC 4.5 all versions, FortiADC 4.4 all versions, FortiADC 4.3 all versions, FortiADC 4.2 all versions, FortiADC 4.1 all versions, FortiADC 4.0 all versions, FortiADC 3.2 all versions, FortiADC 3.1 all versions, FortiADC 3.0 all versions may allow attacker to execute unauthorized code or commands via <insert attack vector here>
An improper neutralization of input during web page generation ('Cross-site Scripting') vulnerability [CWE-79] in FortiADC GUI version 7.4.0, 7.2.0 through 7.2.1 and before 7.1.3 allows an authenticated attacker to perform an XSS attack via crafted HTTP or HTTPs requests.
CVE-2025-26466A flaw was found in the OpenSSH package. For each ping packet the SSH server receives, a pong packet is allocated in a memory buffer and stored in a queue of packages. It is only freed when the server/client key exchange has finished. A malicious client may keep sending such packages, leading to an uncontrolled increase in memory consumption on the server side. Consequently, the server may become unavailable, resulting in a denial of service attack.
A flaw was found in the OpenSSH package. For each ping packet the SSH server receives, a pong packet is allocated in a memory buffer and stored in a queue of packages. It is only freed when the server/client key exchange has finished. A malicious client may keep sending such packages, leading to an uncontrolled increase in memory consumption on the server side. Consequently, the server may become unavailable, resulting in a denial of service attack.
A externally controlled reference to a resource in another sphere vulnerability in Fortinet allows attacker to poison web caches via crafted HTTP requests, where the Host header points to an arbitrary webserver
CVE-2024-6387 A signal handler race condition was found in OpenSSH's server (sshd), where a client does not authenticate within LoginGraceTime seconds (120 by default, 600 in old OpenSSH versions), then sshd's SIGALRM handler is called asynchronously. However, this signal handler calls various functions that are not async-signal-safe, for example, syslog(). This could lead to remote code execution with root privileges.
An improperly implemented security check for standard vulnerability [CWE-358] in FortiADC Web Application Firewall (WAF) 7.4.0 through 7.4.4, 7.2 all versions, 7.1 all versions, 7.0 all versions, 6.2 all versions, 6.1 all versions, 6.0 all versions when cookie security policy is enabled may allow an attacker, under specific conditions, to retrieve the initial encrypted and signed cookie protected by the feature
An improper certificate validation vulnerability [CWE-295] in FortiADC 7.4.0, 7.2.0 through 7.2.3, 7.1 all versions, 7.0 all versions, 6.2 all versions, 6.1 all versions and 6.0 all versions may allow a remote and unauthenticated attacker to perform a Man-in-the-Middle attack on the communication channel between the device and various remote servers such as private SDN connectors and FortiToken Cloud.
An improper access control vulnerability [CWE-284] in Fortinet FortiADC version 7.4.0 through 7.4.1 and before 7.2.4 allows a read only authenticated attacker to perform some write actions via crafted HTTP or HTTPS requests.
An improper certificate validation vulnerability [CWE-295] in FortiADC 7.4.0, 7.2 all versions, 7.1 all versions, 7.0 all versions may allow a remote and unauthenticated attacker to perform a Man-in-the-Middle attack on the communication channel between the device and public SDN connectors.
A security regression (CVE-2006-5051) was discovered in OpenSSH's server (sshd). There is a race condition which can lead sshd to handle some signals in an unsafe manner. An unauthenticated, remote attacker may be able to trigger it by failing to authenticate within a set time period.
An exposure of sensitive system information to an unauthorized control sphere vulnerability [CWE-497] in FortiADC version 7.4.1 and below, version 7.2.3 and below, version 7.1.4 and below, version 7.0.5 and below, version 6.2.6 and below may allow a read-only admin to view data pertaining to other admins.
A fundamental design flaw within the RADIUS protocol has been proven to be exploitable, compromising the integrity in the RADIUS Access-Request process. The attack allows a malicious user to modify packets in a way that would be indistinguishable to a RADIUS client or server. To be successful, the attacker must have the ability to inject themselves between the client and server.
An improper authorization vulnerability [CWE-285] in Fortinet FortiADC version 7.4.0 and before 7.2.2 may allow a low privileged user to read or backup the full system configuration via HTTP or HTTPS requests.
A permissive cross-domain policy with untrusted domains vulnerability in Fortinet FortiADC 7.1.0 - 7.1.1, FortiDDoS-F 6.3.0 - 6.3.4 and 6.4.0 - 6.4.1 allow an unauthorized attacker to carry out privileged actions and retrieve sensitive information via crafted web requests.
Multiple buffer copy without checking size of input ('classic buffer overflow') vulnerabilities [CWE-120] in FortiADC version 7.2.0 and before 7.1.2 & FortiDDoS-F version 6.5.0 and before 6.4.1 allows a privileged attacker to execute arbitrary code or commands via specifically crafted CLI requests.
An improper access control vulnerability [CWE-284] in FortiADC automation feature 7.1.0 through 7.1.2, 7.0 all versions, 6.2 all versions, 6.1 all versions may allow an authenticated low-privileged attacker to escalate their privileges to superadmin via a specific crafted configuration of fabric automation CLI script.
An improper neutralization of special elements used in an OS Command ('OS Command Injection') vulnerability [CWE-78 ] in FortiManager, FortiAnalyzer and FortiADC management interface may allow an authenticated attacker with at least READ permissions on system settings to execute arbitrary commands on the underlying shell due to an unsafe usage of the wordexp function.
An improper neutralization of special elements used in an OS Command ('OS Command Injection') vulnerability [CWE-78 ] in FortiManager 7.2.0 through 7.2.2, 7.0.0 through 7.0.7, 6.4.0 through 6.4.11, 6.2 all versions, 6.0 all versions, FortiAnalyzer 7.2.0 through 7.2.2, 7.0.0 through 7.0.7, 6.4.0 through 6.4.11, 6.2 all versions, 6.0 all versions and FortiADC 7.1.0, 7.0.0 through 7.0.3, 6.2 all versions, 6.1 all versions, 6.0 all versions management interface may allow an authenticated attacker with at least READ permissions on system settings to execute arbitrary commands on the underlying shell due to an unsafe usage of the wordexp function.
An improper neutralization of special elements used in an OS command vulnerability [CWE-78] in the management interface of FortiADC 7.1.0 through 7.1.1, 7.0.0 through 7.0.3, 6.2.0 through 6.2.5 and 6.1.0 all versions may allow an authenticated attacker to execute unauthorized commands via specifically crafted arguments to existing commands.
An improper neutralization of special elements used in an OS command vulnerability [CWE-78] in FortiADC CLI 7.1.0, 7.0.0 through 7.0.3, 6.2.0 through 6.2.4, 6.1 all versions, 6.0 all versions may allow a local and authenticated attacker to execute unauthorized commands via specifically crafted arguments in diagnose system df CLI command.
Multiple improper neutralization of special elements used in an os command ('OS Command Injection') vulnerabilties [CWE-78] in Fortinet FortiADCManager version 7.1.0 and before 7.0.0, FortiADC version 7.2.0 and before 7.1.2 allows a local authenticated attacker to execute arbitrary shell code as root user via crafted CLI requests.
A relative path traversal [CWE-23] in Fortinet FortiADC version 7.2.0 and before 7.1.1 allows a privileged attacker to delete arbitrary directories from the underlying file system via crafted CLI commands.
An improper neutralization of special elements used in an OS command vulnerability [CWE-78] in FortiADC 7.2.0, 7.1.0 through 7.1.1 may allow an authenticated attacker to execute unauthorized commands via specifically crafted arguments to existing commands.
An improper neutralization of input during web page generation ('Cross-site Scripting') vulnerability [CWE-79] in FortiADC version 7.1.1 and below, version 7.0.3 and below, version 6.2.5 and below may allow an authenticated attacker to perform a cross-site scripting attack via crafted HTTP requests.