Latest schneider-electric ecostruxure power monitoring expert Vulnerabilities

A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability that could cause a vulnerability leading to a cross site scripting condition where attackers ...
Schneider-electric Ecostruxure Power Monitoring Expert=2020
Schneider-electric Ecostruxure Power Monitoring Expert=2020-cumulative_update_1
Schneider-electric Ecostruxure Power Monitoring Expert=2020-cumulative_update_2
Schneider-electric Ecostruxure Power Monitoring Expert=2021
Schneider-electric Ecostruxure Power Monitoring Expert=2021-cumulative_update_1
A CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input attackers ca...
Schneider-electric Ecostruxure Power Monitoring Expert=2020
Schneider-electric Ecostruxure Power Monitoring Expert=2020-cumulative_update_1
Schneider-electric Ecostruxure Power Monitoring Expert=2020-cumulative_update_2
Schneider-electric Ecostruxure Power Monitoring Expert=2021
Schneider-electric Ecostruxure Power Monitoring Expert=2021-cumulative_update_1
A CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker to execute arbitrary code on the targeted system by sending a specifically crafted packet to the appli...
Schneider-electric Ecostruxure Power Monitoring Expert
Schneider-electric Ecostruxure Power Operation With Advanced Reports
Schneider-electric Ecostruxure Power Scada Operation With Advanced Reports
A CWE-613: Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain unauthorized access over a hijacked session in PME after the legitimate user has signed out ...
Schneider-electric Ecostruxure Power Monitoring Expert<=2022
Schneider-electric Ecostruxure Power Monitoring Expert<=2020
A CWE-20: Improper Input Validation vulnerability exists that could allow arbitrary files on the server to be read by authenticated users through a limited operating system service account. Affected P...
Schneider-electric Ecostruxure Power Monitoring Expert<=2020
A CWE-20: Improper Input Validation vulnerability exists that could allow an unauthenticated attacker to view data, change settings, impact availability of the software, or potentially impact a user?s...
Schneider-electric Ecostruxure Power Monitoring Expert<=2020
A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22826. ...
Schneider-electric Ecostruxure Power Monitoring Expert<=9.0
A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22827. ...
Schneider-electric Ecostruxure Power Monitoring Expert<=9.0
A CWE-284: Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow a us...
Schneider-electric Ecostruxure Energy Expert=2.0
Schneider-electric Ecostruxure Power Monitoring Expert=7.0
Schneider-electric Ecostruxure Power Monitoring Expert=8.0
Schneider-electric Ecostruxure Power Monitoring Expert=9.0
Schneider-electric Power Manager=1.1
Schneider-electric Power Manager=1.2
and 3 more
A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version...
Schneider-electric Ecostruxure Energy Expert=2.0
Schneider-electric Ecostruxure Power Monitoring Expert=7.0
Schneider-electric Ecostruxure Power Monitoring Expert=8.0
Schneider-electric Ecostruxure Power Monitoring Expert=9.0
Schneider-electric Power Manager=1.1
Schneider-electric Power Manager=1.2
and 3 more
A CWE-284:Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow for a...
Schneider-electric Ecostruxure Energy Expert=2.0
Schneider-electric Ecostruxure Power Monitoring Expert=7.0
Schneider-electric Ecostruxure Power Monitoring Expert=8.0
Schneider-electric Ecostruxure Power Monitoring Expert=9.0
Schneider-electric Power Manager=1.1
Schneider-electric Power Manager=1.2
and 3 more
A URL redirection vulnerability exists in Power Monitoring Expert, Energy Expert (formerly Power Manager) - EcoStruxure Power Monitoring Expert (PME) v8.2 (all editions), EcoStruxure Energy Expert 1.3...
Schneider-electric Ecostruxure Energy Expert=1.3
Schneider-electric Ecostruxure Energy Expert=2.0
Schneider-electric Ecostruxure Power Monitoring Expert=8.2
Schneider-electric Ecostruxure Power Monitoring Expert=9.0
Schneider-electric Ecostruxure Power Scada Operation=8.2
Schneider-electric Ecostruxure Power Scada Operation=9.0

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.