It was possible for an authenticated non-admin user to modify certain data objects without having the appropriate permissions, which could be used to tamper with audit log creation in AXIS Camera Station.
Database backups are vulnerable to offline attacks. Backups created using a version prior to the patched version are still vulnerable. AXIS Camera Station Pro automatically creates one more such backup for recovery purpose when the update is applied. Delete all these backups and change the credentials stored in AXIS Camera Station Pro.
An ACAP configuration file lacks input validation, which could potentially lead to privilege escalation. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application.
A configuration file on the local file system had improper input validation which could allow code execution and potentially lead to privilege escalation. This vulnerability can only be exploited if an attacker can log in to the Axis device using SSH.
An ACAP configuration file lacked sufficient input validation, which could allow a path traversal attack leading to potential privilege escalation. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application.
An ACAP configuration file lacked sufficient input validation, which could allow command injection and potentially lead to privilege escalation. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application.
ACAP applications can gain elevated privileges due to improper input validation during the installation process, potentially leading to privilege escalation. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application.
An insecure direct object reference allowed a non-admin user to modify or remove certain data objects without having the appropriate permissions.
An AXIS Camera Station Pro feature can be exploited in a way that allows a non-admin user to view information they are not permitted to.
A server-side injection was possible for a malicious admin to manipulate the application to include a malicious script which is executed by the server. This attack is only possible if the admin uses a client that have been tampered with.
AXIS Camera Station Pro contained a flaw to perform a privilege escalation attack on the server as a non-admin user.
The VAPIX API mediaclip.cgi that did not have a sufficient input validation allowing for a possible remote code execution. This flaw can only be exploited after authenticating with an operator- or administrator- privileged service account.
AXIS Optimizer was vulnerable to an unquoted search path vulnerability, which could potentially lead to privilege escalation within Microsoft Windows operating system. This vulnerability can only be exploited if the attacker has access to the local Windows machine and sufficient access rights (administrator) to write data into the installation path of AXIS Optimizer.
An ACAP configuration file has improper permissions and lacks input validation, which could potentially lead to privilege escalation. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application.
An ACAP configuration file has improper permissions, which could allow command injection and potentially lead to privilege escalation. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application.
A malicious ACAP application can gain access to admin-level service account credentials used by legitimate ACAP applications, leading to potential privilege escalation of the malicious ACAP application. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application.
ACAP applications can gain elevated privileges due to improper input validation, potentially leading to privilege escalation. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application.
The ACAP Application framework could allow privilege escalation through a symlink attack. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application.
An ACAP configuration file lacked sufficient input validation, which could allow a path traversal attack leading to potential privilege escalation. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application.
An ACAP configuration file lacked sufficient input validation, which could allow for arbitrary code execution. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application.
An ACAP configuration file lacked sufficient input validation, which could allow for arbitrary code execution. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application.
ACAP applications can be executed with elevated privileges, potentially leading to privilege escalation. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application.
During an internal security assessment, a Server-Side Request Forgery (SSRF) vulnerability that allowed an authenticated attacker to access internal resources on the server was discovered.
The AXIS Camera Station Server had a flaw that allowed to bypass authentication that is normally required.
The communication protocol used between the server process and the service control had a flaw that could lead to a local privilege escalation.
The communication protocol used between client and server had a flaw that could be leveraged to execute a man in the middle attack.
The communication protocol used between client and server had a flaw that could lead to an authenticated user performing a remote code execution attack.
During an annual penetration test conducted on behalf of Axis Communication, Truesec discovered a flaw in the VAPIX Device Configuration framework that allowed a privilege escalation, enabling a lower-privileged user to gain administrator privileges.
A Guard Tour VAPIX API parameter allowed the use of arbitrary values and can be incorrectly called, allowing an attacker to block access to the guard tour configuration page in the web interface of the Axis device.