Where
AND
-Infinity
0
Severity
6.5
CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:L/A:N

CloudBees CD Plugin unconditionally disabled SSL/TLS certificate validation for the entire Jenkins controller JVM during the deployment/publication of an application.

CloudBees CD Plugin no longer does that. Instead, the existing opt-in option to ignore SSL/TLS errors is used during deployment for the specific connection.

This issue was caused by an incomplete fix for SECURITY-937.

1 / 2
First published (updated )
Severity
4.3
CSRF
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N

A missing permission check in a form validation method in CloudBees CD Plugin allowed users with Overall/Read permission to initiate a connection test to an attacker-specified server with attacker-specified username and password.

Additionally, the form validation method did not require POST requests, resulting in a CSRF vulnerability.

This form validation method now requires POST requests and Overall/Administer permissions.

1 / 2
First published (updated )
Severity
4.3
CSRF
CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N

A cross-site request forgery vulnerability in Jenkins ElectricFlow Plugin 1.1.5 and earlier in Configuration#doTestConnection allowed attackers to connect to an attacker-specified URL using attacker-specified credentials.

1 / 2
First published (updated )
Severity
4.3
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N

Missing permission checks in Jenkins ElectricFlow Plugin 1.1.5 and earlier in various HTTP endpoints allowed users with Overall/Read access to obtain information about the Jenkins ElectricFlow Plugin configuration and configuration of connected ElectricFlow instances.

1 / 2
First published (updated )
Severity
5.4
XSS
CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N

A stored cross site scripting vulnerability in Jenkins ElectricFlow Plugin 1.1.5 and earlier allowed attackers able to configure jobs in Jenkins or control the output of the ElectricFlow API to inject arbitrary HTML and JavaScript in the plugin-provided output on build status pages.

1 / 2
First published (updated )
Severity
6.1
XSS
CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

A reflected cross site scripting vulnerability in Jenkins ElectricFlow Plugin 1.1.6 and earlier allowed attackers able to control the output of the ElectricFlow API to inject arbitrary HTML and JavaScript in job configuration forms containing post-build steps provided by this plugin.

1 / 2
First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.