Where
AND
-Infinity
0
Severity
6.8
AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

A Return of Pointer Value Outside of Expected Range vulnerability in the fileio library of Juniper Networks Junos OS and Junos OS Evolved allows a local, low-privilged attacker to cause a Denial-of-Service (DoS).

On EX Series, QFX Series and MX Series a low-privileged attacker issuing a specific 'show l2-learning' or 'show ethernet-switching' command will cause an l2ald crash which will lead to a temporary service impact for all layer 2 services until the process has automatically restarted.

This issue affects EX Series, QFX Series, MX Series: Junos OS:

all versions before 23.2R2-S7, 23.4 versions before 23.4R2-S7, 24.2 versions before 24.2R2, 24.4 versions before 24.4R1-S2.

Junos OS Evolved: all versions before 23.2R2-S7-EVO, 23.4 versions before 23.4R2-S8-EVO, 24.2 versions before 24.2R2-EVO, 24.4 versions before 24.4R1-S3-EVO.

First published (updated )
Severity
6.9
AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N

An Incorrect Initialization of Resource vulnerability in the packet forwarding engine (pfe) of Juniper Networks Junos OS on specific EX Series and QFX Series device allows an unauthenticated, network-based attacker to cause an integrity impact to downstream networks.

When the same family inet or inet6 filter is applied on an IRB interface and on a physical interface as egress filter on EX4100, EX4400, EX4650 and QFX5120 devices, only one of the two filters will be applied, which can lead to traffic being sent out one of these interfaces which should have been blocked.

This issue affects Junos OS on EX Series and QFX Series: 23.4 version 23.4R2-S6, 24.2 version 24.2R2-S3.

No other Junos OS versions are affected.

First published (updated )
Severity
6.8
Null Pointer Dereference
AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

A NULL Pointer Dereference vulnerability in the chassis daemon (chassisd) of Juniper Networks Junos OS on MX, SRX and EX Series allows a local attacker with low privileges to cause a Denial-of-Service (DoS).

When a user executes the 'show chassis' command with specifically crafted options, chassisd will crash and restart. Due to this all components but the Routing Engine (RE) in the chassis are reinitialized, which leads to a complete service outage, which the system automatically recovers from.

This issue affects:

Junos OS on MX, SRX and EX Series, except MX10000 Series and MX304:

all versions before 22.4R3-S8, 23.2 versions before 23.2R2-S5, 23.4 versions before 23.4R2-S6, 24.2 versions before 24.2R2-S2, 24.4 versions before 24.4R2.

First published (updated )
Severity
6.9
EPSS
0.04%
AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N

An Incorrect Behavior Order vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS on EX4300 Series allows an unauthenticated, network-based attacker to cause an integrity impact to networks downstream of the vulnerable device.

When an output firewall filter is applied to an interface it doesn't recognize matching packets but permits any traffic. This issue affects Junos OS 21.4 releases from 21.4R1 earlier than 21.4R3-S6. This issue does not affect Junos OS releases earlier than 21.4R1.

Remedy

The following software release has been updated to resolve this specific issue: 21.4R3-S6, and all subsequent releases of this branch.
First published (updated )
Severity
6.8
EPSS
0.04%
AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

An Improper Check for Unusual or Exceptional Conditions vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS on EX4300 Series allows a locally authenticated attacker with low privileges to cause a Denial-of-Service (Dos).

If a specific CLI command is issued, a PFE crash will occur. This will cause traffic forwarding to be interrupted until the system self-recovers.

This issue affects Junos OS:

All versions before 20.4R3-S10,

21.2 versions before 21.2R3-S7,

21.4 versions before 21.4R3-S6.

Remedy

The following software releases have been updated to resolve this specific issue: 20.4R3-S10, 21.2R3-S7, 21.4R3-S6, and all subsequent releases of these branches.
First published (updated )
Severity
6.9
EPSS
0.04%
AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N

An Incorrect Behavior Order in the routing engine (RE) of Juniper Networks Junos OS on EX4300 Series allows traffic intended to the device to reach the RE instead of being discarded when the discard term is set in loopback (lo0) interface. The intended function is that the lo0 firewall filter takes precedence over the revenue interface firewall filter.

This issue affects only IPv6 firewall filter.

This issue only affects the EX4300 switch. No other products or platforms are affected by this vulnerability.

This issue affects Juniper Networks Junos OS:

All versions before 20.4R3-S10, from 21.2 before 21.2R3-S7, from 21.4 before 21.4R3-S6.

Remedy

The following software releases have been updated to resolve this specific issue:  Junos OS: 20.4R3-S10, 21.2R3-S7, 21.4R3-S6, and all subsequent releases.
First published (updated )
Severity
5.3
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N

A Missing Authentication for Critical Function vulnerability in Juniper Networks Junos OS on SRX Series allows an unauthenticated, network-based attacker to cause limited impact to the file system integrity.

With a specific request to

webauthoperation.php

that doesn't require authentication, an attacker is able to upload and download arbitrary files via J-Web, leading to a loss of

integrity or confidentiality, which may allow chaining to other vulnerabilities.

This issue affects Juniper Networks Junos OS on SRX Series:

21.2 versions prior to 21.2R3-S8; 21.4

versions prior to

21.4R3-S6; 22.1

versions prior to

22.1R3-S5; 22.2

versions prior to

22.2R3-S3; 22.3

versions prior to

22.3R3-S2; 22.4 versions prior to 22,4R2-S2, 22.4R3; 23.2 versions prior to

23.2R1-S2, 23.2R2.

1 / 3
Source: NVD
First published (updated )
Severity
5.3
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N

A Missing Authentication for Critical Function vulnerability in Juniper Networks Junos OS on SRX Series allows an unauthenticated, network-based attacker to cause limited impact to the file system integrity.

With a specific request to user.php that doesn't require authentication an attacker is able to upload arbitrary files via J-Web, leading to a loss of

integrity

for a certain

part of the file system, which may allow chaining to other vulnerabilities.

This issue affects Juniper Networks Junos OS on SRX Series:

All versions prior to 20.4R3-S8; 21.1 versions 21.1R1 and later; 21.2 versions prior to 21.2R3-S6; 21.3 versions

prior to

21.3R3-S5; 21.4 versions

prior to

21.4R3-S5; 22.1 versions

prior to

22.1R3-S3; 22.2 versions

prior to

22.2R3-S2; 22.3 versions

prior to

22.3R2-S2, 22.3R3; 22.4 versions

prior to

22.4R2-S1, 22.4R3.

1 / 2
Source: NVD
First published (updated )
Severity
5.3
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N

A PHP External Variable Modification vulnerability in J-Web of Juniper Networks Junos OS on EX Series allows an unauthenticated, network-based attacker to control certain, important environment variables.

Using a crafted request an attacker is able to modify

certain PHP environment variables leading to partial loss of integrity, which may allow chaining to other vulnerabilities. This issue affects Juniper Networks Junos OS on EX Series:

All versions prior to 20.4R3-S9; 21.1 versions 21.1R1 and later; 21.2 versions prior to 21.2R3-S7; 21.3 versions

prior to

21.3R3-S5; 21.4 versions

prior to

21.4R3-S5; 22.1 versions

prior to

22.1R3-S4; 22.2 versions

prior to

22.2R3-S2; 22.3 versions

prior to 22.3R3-S1; 22.4 versions

prior to

22.4R2-S2, 22.4R3; 23.2 versions prior to

23.2R1-S1, 23.2R2.

1 / 2
Source: NVD
First published (updated )
Severity
5.3
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N

A Missing Authentication for Critical Function vulnerability in Juniper Networks Junos OS on EX Series allows an unauthenticated, network-based attacker to cause limited impact to the file system integrity.

With a specific request to installAppPackage.php that doesn't require authentication an attacker is able to upload arbitrary files via J-Web, leading to a loss of

integrity

for a certain

part of the file system, which may allow chaining to other vulnerabilities.

This issue affects Juniper Networks Junos OS on EX Series:

All versions prior to 20.4R3-S8; 21.1 versions 21.1R1 and later; 21.2 versions prior to 21.2R3-S6; 21.3 versions

prior to

21.3R3-S5; 21.4 versions

prior to

21.4R3-S4; 22.1 versions

prior to

22.1R3-S3; 22.2 versions

prior to

22.2R3-S1; 22.3 versions

prior to

22.3R2-S2, 22.3R3; 22.4 versions

prior to

22.4R2-S1, 22.4R3.

1 / 2
Source: NVD
First published (updated )
Severity
6.5
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

In VxLAN scenarios on EX4300-MP, EX4600, QFX5000 Series devices an Uncontrolled Memory Allocation vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS allows an unauthenticated adjacently located attacker sending specific packets to cause a Denial of Service (DoS) condition by crashing one or more PFE's when they are received and processed by the device. Upon automatic restart of the PFE, continued processing of these packets will cause the memory leak to reappear. Depending on the volume of packets received the attacker may be able to create a sustained Denial of Service (DoS) condition. This issue affects: Juniper Networks Junos OS on EX4300-MP, EX4600, QFX5000 Series: 17.1 version 17.1R1 and later versions prior to 17.3R3-S12; 17.4 versions prior to 17.4R2-S13, 17.4R3-S5; 18.1 versions prior to 18.1R3-S13; 18.2 versions prior to 18.2R3-S8; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R1-S8, 18.4R2-S6, 18.4R3-S6; 19.1 versions prior to 19.1R3-S4; 19.2 versions prior to 19.2R1-S7, 19.2R3-S1; 19.3 versions prior to 19.3R2-S6, 19.3R3-S1; 19.4 versions prior to 19.4R1-S4, 19.4R2-S4, 19.4R3-S1; 20.1 versions prior to 20.1R2; 20.2 versions prior to 20.2R2-S3, 20.2R3; 20.3 versions prior to 20.3R2. This issue does not affect Junos OS versions prior to 17.1R1.

Remedy

The following software releases have been updated to resolve this specific issue: 17.3R3-S12, 17.4R2-S13, 17.4R3-S5, 18.1R3-S13, 18.2R3-S8, 18.3R3-S5, 18.4R1-S8, 18.4R2-S6, 18.4R3-S6, 19.1R3-S4, 19.2R1-S7, 19.2R3-S1, 19.3R2-S6, 19.3R3-S1, 19.4R1-S4, 19.4R2-S4, 19.4R3-S1, 20.1R2, 20.2R2-S3, 20.2R3, 20.3R2, 20.4R1, and all subsequent releases.
First published (updated )
Severity
6.5
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

An Uncontrolled Resource Consumption vulnerability in Juniper Networks Junos OS on EX2300, EX3400 and EX4300 Series platforms allows an adjacent attacker sending a stream of layer 2 frames will trigger an Aggregated Ethernet (AE) interface to go down and thereby causing a Denial of Service (DoS). By continuously sending a stream of specific layer 2 frames an attacker will sustain the Denial of Service (DoS) condition. This issue affects: Juniper Networks Junos OS EX4300 Series All versions prior to 15.1R7-S7; 16.1 versions prior to 16.1R7-S8; 17.1 versions prior to 17.1R2-S12; 17.2 versions prior to 17.2R3-S4; 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R2-S10, 17.4R3-S2; 18.1 versions prior to 18.1R3-S10; 18.2 versions prior to 18.2R2-S7, 18.2R3-S3; 18.3 versions prior to 18.3R2-S4, 18.3R3-S2; 18.4 versions prior to 18.4R1-S7, 18.4R2-S4, 18.4R3-S1; 19.1 versions prior to 19.1R1-S5, 19.1R2-S1, 19.1R3; 19.2 versions prior to 19.2R1-S5, 19.2R2; 19.3 versions prior to 19.3R2-S2, 19.3R3; 19.4 versions prior to 19.4R1-S2, 19.4R2. Juniper Networks Junos OS EX3400 and EX4300-MP Series All versions prior to 18.1R3-S12; 18.2 versions prior to 18.2R3-S7; 18.3 versions prior to 18.3R3-S4; 18.4 versions prior to 18.4R2-S9, 18.4R3-S7; 19.1 versions prior to 19.1R2-S3, 19.1R3-S4; 19.2 versions prior to 19.2R3-S1; 19.3 versions prior to 19.3R3-S1; 19.4 versions prior to 19.4R3-S1; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R3; 20.3 versions prior to 20.3R2. Juniper Networks Junos OS EX2300 Series All versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R2-S9, 18.4R3-S9; 19.1 versions prior to 19.1R2-S3, 19.1R3-S6; 19.2 versions prior to 19.2R1-S7, 19.2R3-S3; 19.3 versions prior to 19.3R2-S7, 19.3R3-S3; 19.4 versions prior to 19.4R3-S5; 20.1 versions prior to 20.1R2-S2, 20.1R3-S1; 20.2 versions prior to 20.2R3-S2; 20.3 versions prior to 20.3R3-S1; 20.4 versions prior to 20.4R2-S1, 20.4R3; 21.1 versions prior to 21.1R2.

Remedy

The following software releases have been updated to resolve this specific issue in Junos OS - For EX4300 Series: 15.1R7-S7, 16.1R7-S8, 17.1R2-S12, 17.2R3-S4, 17.3R3-S8, 17.4R2-S10, 17.4R3-S2, 18.1R3-S10, 18.2R2-S7, 18.2R3-S3, 18.3R2-S4, 18.3R3-S2, 18.4R1-S7, 18.4R2-S4, 18.4R3-S1, 19.1R1-S5, 19.1R2-S1, 19.1R3, 19.2R2, 19.3R2-S2, 19.3R3, 19.4R1-S2, 19.4R2, 20.1R1, and all subsequent releases. - For EX3400 and EX4300-MP Series: 18.1R3-S12, 18.2R3-S7, 18.3R3-S4, 18.4R2-S9, 18.4R3-S7, 19.1R2-S3, 19.1R3-S4, 19.2R3-S1, 19.3R3-S1, 19.4R3-S1, 20.1R3, 20.2R3, 20.3R2, 20.4R1, and all subsequent releases. -For EX2300 Series: 18.3R3-S5, 18.4R2-S9, 18.4R3-S9, 19.1R2-S3, 19.1R3-S6, 19.2R1-S7, 19.2R3-S3, 19.3R2-S7, 19.3R3-S3, 19.4R3-S5, 20.1R2-S2, 20.1R3-S1, 20.2R3-S2, 20.3R3-S1, 20.4R2-S1, 20.4R3, 21.1R2, 21.2R1, and all subsequent releases.
First published (updated )
Severity
6.5
Race Condition
CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H

When user-defined ARP Policer is configured and applied on one or more Aggregated Ethernet (AE) interface units, a Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability between the Device Control Daemon (DCD) and firewall process (dfwd) daemons of Juniper Networks Junos OS allows an attacker to bypass the user-defined ARP Policer. In this particular case the User ARP policer is replaced with default ARP policer. To review the desired ARP Policers and actual state one can run the command "show interfaces <> extensive" and review the output. See further details below. An example output is: show interfaces extensive | match policer Policer: Input: defaultarppolicer <<< incorrect if user ARP Policer was applied on an AE interface and the default ARP Policer is displayed Policer: Input: jtac-arp-ae5.317-inet-arp <<< correct if user ARP Policer was applied on an AE interface For all platforms, except SRX Series: This issue affects Juniper Networks Junos OS: All versions 5.6R1 and all later versions prior to 18.4 versions prior to 18.4R2-S9, 18.4R3-S9 with the exception of 15.1 versions 15.1R7-S10 and later versions; 19.4 versions prior to 19.4R3-S3; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R3-S2; 20.3 version 20.3R1 and later versions; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2; This issue does not affect Juniper Networks Junos OS versions prior to 5.6R1. On SRX Series this issue affects Juniper Networks Junos OS: 18.4 versions prior to 18.4R2-S9, 18.4R3-S9; 19.4 versions prior to 19.4R3-S4; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R3-S2; 20.3 version 20.3R1 and later versions; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2. This issue does not affect 18.4 versions prior to 18.4R1 on SRX Series. This issue does not affect Junos OS Evolved.

First published (updated )
Severity
6.5
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

On Juniper Networks EX4300-MP Series, EX4600 Series, EX4650 Series, QFX5K Series deployed as a Virtual Chassis with a specific Layer 2 circuit configuration, Packet Forwarding Engine manager (FXPC) process may crash and restart upon receipt of specific layer 2 frames. Continued receipt and processing of this packet will create a sustained Denial of Service (DoS) condition. This issue affects: Juniper Networks Junos OS on EX4300-MP Series, EX4600 Series, EX4650 Series, QFX5K Series 15.1 versions prior to 15.1R7-S9; 17.3 versions prior to 17.3R3-S11; 17.4 versions prior to 17.4R2-S13, 17.4R3-S4, 17.4R3-S5; 18.2 versions prior to 18.2R3-S8; 18.3 versions prior to 18.3R3-S4; 18.4 versions prior to 18.4R2-S7, 18.4R3-S6; 19.1 versions prior to 19.1R3-S4; 19.2 versions prior to 19.2R1-S6, 19.2R3-S1; 19.3 versions prior to 19.3R3-S1; 19.4 versions prior to 19.4R2-S4, 19.4R3-S1; 20.1 versions prior to 20.1R2; 20.2 versions prior to 20.2R2, 20.2R3; 20.3 versions prior to 20.3R1-S2, 20.3R2;

Remedy

The following software releases have been updated to resolve this specific issue: 15.1R7-S9, 17.3R3-S11, 17.4R2-S13, 17.4R3-S4, 17.4R3-S5, 18.3R3-S4, 18.4R2-S7, 18.4R3-S6, 19.1R3-S4, 19.2R1-S6, 19.2R3-S1, 19.3R3-S1, 19.4R2-S4, 19.4R3-S1, 20.1R2, 20.2R2, 20.2R3, 20.3R1-S2, 20.3R2, 20.4R1, and all subsequent releases.
First published (updated )
Severity
6.5
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

On Juniper Networks EX4300-MP Series, EX4600 Series and QFX5K Series deployed in a Virtual Chassis configuration, receipt of a stream of specific layer 2 frames can cause high CPU load, which could lead to traffic interruption. This issue does not occur when the device is deployed in Stand Alone configuration. The offending layer 2 frame packets can originate only from within the broadcast domain where the device is connected. This issue affects Juniper Networks Junos OS on EX4300-MP Series, EX4600 Series and QFX5K Series: 17.3 versions prior to 17.3R3-S9; 17.4 versions prior to 17.4R2-S11, 17.4R3-S2, 17.4R3-S3; 18.1 versions prior to 18.1R3-S11; 18.2 versions prior to 18.2R3-S5; 18.3 versions prior to 18.3R2-S4, 18.3R3-S3; 18.4 versions prior to 18.4R2-S5, 18.4R3-S4; 19.1 versions prior to 19.1R3-S2; 19.2 versions prior to 19.2R1-S5, 19.2R3; 19.3 versions prior to 19.3R2-S4, 19.3R3; 19.4 versions prior to 19.4R1-S3, 19.4R2-S1, 19.4R3; 20.1 versions prior to 20.1R1-S3, 20.1R2.

Remedy

The following software releases have been updated to resolve this specific issue: Junos OS 17.3R3-S9, 17.4R2-S11, 17.4R3-S2, 17.4R3-S3, 18.1R3-S11, 18.2R3-S5, 18.3R2-S4, 18.3R3-S3, 18.4R2-S5, 18.4R3-S4, 19.1R3-S2, 19.2R1-S5, 19.2R3, 19.3R2-S4, 19.3R3, 19.4R1-S3, 19.4R2-S1, 19.4R3, 20.1R1-S3, 20.1R2, 20.2R1, and all subsequent releases.
First published (updated )
Severity
5.3
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L

On Juniper Networks Junos OS devices configured as a DHCP forwarder, the Juniper Networks Dynamic Host Configuration Protocol Daemon (jdhcp) process might crash when receiving a malformed DHCP packet. This issue only affects devices configured as DHCP forwarder with forward-only option, that forward specified DHCP client packets, without creating a new subscriber session. The jdhcpd daemon automatically restarts without intervention, but continuous receipt of the malformed DHCP packet will repeatedly crash jdhcpd, leading to an extended Denial of Service (DoS) condition. This issue can be triggered only by DHCPv4, it cannot be triggered by DHCPv6. This issue affects Juniper Networks Junos OS: 12.3 versions prior to 12.3R12-S16; 12.3X48 versions prior to 12.3X48-D105 on SRX Series; 14.1X53 versions prior to 14.1X53-D60 on EX and QFX Series; 15.1 versions prior to 15.1R7-S7; 15.1X49 versions prior to 15.1X49-D221, 15.1X49-D230 on SRX Series; 15.1X53 versions prior to 15.1X53-D593 on EX2300/EX3400; 16.1 versions prior to 16.1R7-S5.

Remedy

The following software releases have been updated to resolve this specific issue: Junos OS 12.3R12-S16, 12.3X48-D105, 15.1R7-S7, 15.1X49-D221, 15.1X49-D230, 15.1X53-D593, 16.1R7-S5, 16.2R1 and all subsequent releases.
First published (updated )
Severity
5.3
Infoleak
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N

Juniper Networks Junos OS uses the 128.0.0.0/2 subnet for internal communications between the RE and PFEs. It was discovered that packets utilizing these IP addresses may egress an EX4300 switch, leaking configuration information such as heartbeats, kernel versions, etc. out to the Internet, leading to an information exposure vulnerability. This issue affects Juniper Networks Junos OS: 14.1X53 versions prior to 14.1X53-D53 on EX4300; 15.1 versions prior to 15.1R7-S6 on EX4300; 15.1X49 versions prior to 15.1X49-D200, 15.1X49-D210 on EX4300; 16.1 versions prior to 16.1R7-S7 on EX4300; 17.1 versions prior to 17.1R2-S11, 17.1R3-S2 on EX4300; 17.2 versions prior to 17.2R3-S3 on EX4300; 17.3 versions prior to 17.3R2-S5, 17.3R3-S7 on EX4300; 17.4 versions prior to 17.4R2-S9, 17.4R3 on EX4300; 18.1 versions prior to 18.1R3-S8 on EX4300; 18.2 versions prior to 18.2R3-S2 on EX4300; 18.3 versions prior to 18.3R2-S3, 18.3R3, 18.3R3-S1 on EX4300; 18.4 versions prior to 18.4R1-S5, 18.4R2-S3, 18.4R3 on EX4300; 19.1 versions prior to 19.1R1-S4, 19.1R2 on EX4300; 19.2 versions prior to 19.2R1-S4, 19.2R2 on EX4300; 19.3 versions prior to 19.3R1-S1, 19.3R2 on EX4300.

First published (updated )
Severity
6.9
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

On Juniper Networks EX and QFX Series, an authentication bypass vulnerability may allow a user connected to the console port to login as root without any password. This issue might only occur in certain scenarios: • At the first reboot after performing device factory reset using the command “request system zeroize”; or • A temporary moment during the first reboot after the software upgrade when the device configured in Virtual Chassis mode. This issue affects Juniper Networks Junos OS on EX and QFX Series: 14.1X53 versions prior to 14.1X53-D53; 15.1 versions prior to 15.1R7-S4; 15.1X53 versions prior to 15.1X53-D593; 16.1 versions prior to 16.1R7-S4; 17.1 versions prior to 17.1R2-S11, 17.1R3-S1; 17.2 versions prior to 17.2R3-S3; 17.3 versions prior to 17.3R2-S5, 17.3R3-S6; 17.4 versions prior to 17.4R2-S9, 17.4R3; 18.1 versions prior to 18.1R3-S8; 18.2 versions prior to 18.2R2; 18.3 versions prior to 18.3R1-S7, 18.3R2. This issue does not affect Juniper Networks Junos OS 12.3.

First published (updated )
Severity
6.5
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N

On EX4300, EX4600, QFX3500, and QFX5100 Series, a vulnerability in the IP firewall filter component may cause the firewall filter evaluation of certain packets to fail. This issue only affects firewall filter evaluation of certain packets destined to the device Routing Engine (RE). This issue does not affect the Layer 2 firewall filter evaluation nor does it affect the Layer 3 firewall filter evaluation destined to connected hosts. This issue may occur when evaluating both IPv4 or IPv6 packets. This issue affects Juniper Networks Junos OS: 14.1X53 versions prior to 14.1X53-D12 on QFX5100 Series and EX4600 Series; 14.1X53 versions prior to 14.1X53-D52 on QFX3500 Series; 14.1X53 versions prior to 14.1X53-D48 on EX4300 Series; 15.1 versions prior to 15.1R7-S3 on EX4300 Series; 16.1 versions prior to 16.1R7 on EX4300 Series; 17.1 versions prior to 17.1R3 on EX4300 Series; 17.2 versions prior to 17.2R3 on EX4300 Series; 17.3 versions prior to 17.3R2-S5, 17.3R3 on EX4300 Series; 17.4 versions prior to 17.4R2 on EX4300 Series; 18.1 versions prior to 18.1R3 on EX4300 Series; 18.2 versions prior to 18.2R2 on EX4300 Series.

First published (updated )
Severity
5.8
Infoleak
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N

On EX4300 Series switches with TCAM optimization enabled, incoming multicast traffic matches an implicit loopback filter rule first, since it has high priority. This rule is meant for reserved multicast addresses 224.0.0.x, but incorrectly matches on 224.x.x.x. Due to this bug, when a firewall filter is applied on the loopback interface, other firewall filters might stop working for multicast traffic. The command 'show firewall filter' can be used to confirm whether the filter is working. This issue only affects the EX4300 switch. No other products or platforms are affected by this vulnerability. This issue affects: Juniper Networks Junos OS: 14.1X53 versions prior to 14.1X53-D51, 14.1X53-D115 on EX4300 Series; 17.1 versions prior to 17.1R3 on EX4300 Series; 17.2 versions prior to 17.2R3-S2 on EX4300 Series; 17.3 versions prior to 17.3R3-S3 on EX4300 Series; 17.4 versions prior to 17.4R2-S5, 17.4R3 on EX4300 Series; 18.1 versions prior to 18.1R3-S1 on EX4300 Series; 18.2 versions prior to 18.2R2 on EX4300 Series; 18.3 versions prior to 18.3R2 on EX4300 Series.

Remedy

The following software releases have been updated to resolve this specific issue: 14.1X53-D51, 14.1X53-D115, 17.1R3, 17.2R3-S2, 17.3R3-S3, 17.4R2-S5, 17.4R3, 18.1R3-S1, 18.2R2, 18.3R2, 18.4R1, and all subsequent releases.
First published (updated )
Severity
5.9
Input Validation
CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H

A Denial of Service vulnerability exists in the Juniper Networks Junos OS JDHCPD daemon which allows an attacker to core the JDHCPD daemon by sending a crafted IPv6 packet to the system. This issue is limited to systems which receives IPv6 DHCP packets on a system configured for DHCP processing using the JDHCPD daemon. This issue does not affect IPv4 DHCP packet processing. Affected releases are Juniper Networks Junos OS: 12.3 versions prior to 12.3R12-S10 on EX Series; 12.3X48 versions prior to 12.3X48-D70 on SRX Series; 14.1X53 versions prior to 14.1X53-D47 on EX2200/VC, EX3200, EX3300/VC, EX4200, EX4300, EX4550/VC, EX4600, EX6200, EX8200/VC (XRE), QFX3500, QFX3600, QFX5100; 14.1X53 versions prior to 14.1X53-D130 on QFabric; 15.1 versions prior to 15.1R4-S9, 15.1R6-S6, 15.1R7; 15.1X49 versions prior to 15.1X49-D140 on SRX Series; 15.1X53 versions prior to 15.1X53-D67 on QFX10000 Series; 15.1X53 versions prior to 15.1X53-D233 on QFX5110, QFX5200; 15.1X53 versions prior to 15.1X53-D471 on NFX 150, NFX 250; 16.1 versions prior to 16.1R3-S9, 16.1R4-S8, 16.1R5-S4, 16.1R6-S3, 16.1R7; 16.2 versions prior to 16.2R2-S5, 16.2R3; 17.1 versions prior to 17.1R1-S7, 17.1R2-S7, 17.1R3; 17.2 versions prior to 17.2R1-S6, 17.2R2-S4, 17.2R3; 17.3 versions prior to 17.3R1-S4, 17.3R2-S2, 17.3R3; 17.4 versions prior to 17.4R1-S3, 17.4R2.

Remedy

The following software releases have been updated to resolve this specific issue: Junos OS 12.3R12-S10, 12.3X48-D70, 14.1X53-D130*, 14.1X53-D47, 15.1R4-S9, 15.1R6-S6, 15.1R7, 15.1X49-D140, 15.1X53-D233, 15.1X53-D471, 15.1X53-D67, 16.1R3-S9, 16.1R4-S8, 16.1R5-S4, 16.1R6-S3, 16.1R7, 16.2R2-S5, 16.2R3, 17.1R1-S7, 17.1R2-S7, 17.1R3, 17.2R1-S6, 17.2R2-S4, 17.2R3, 17.3R1-S4, 17.3R2-S2, 17.3R3, 17.4R1-S3, 17.4R2, 18.1R1, and all subsequent releases. *Pending Publication
First published (updated )
Severity
5
Null Pointer Dereference
AV:N/AC:L/Au:N/C:N/I:N/A:P

Embedthis Appweb before 4.6.6 and 5.x before 5.2.1 allows remote attackers to cause a denial of service (NULL pointer dereference) via a Range header with an empty value, as demonstrated by "Range: x=,".

First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203